Abstract
Nuclear magnetic resonance (NMR) is widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging (MRI). Recently it has become possible to perform NMR and MRI in the ultra-low field (ULF) regime requiring measurement field strengths of the order of only 1 Gauss. This technique exploits the advantages offered by superconducting quantum interference devices or SQUIDs. Our group has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airport security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers may provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR technique. We describe experimental and computer-simulation results comparing multichannel SQUID based and induction coils based instruments that are capable of performing ULF MRI for liquid identification.Keywords
This publication has 13 references indexed in Scilit:
- Ultra-low-field MRI for the detection of liquid explosivesSuperconductor Science and Technology, 2010
- Ultra-Low Field NMR of ${\rm UF}_{6}$ for $^{235}{\rm U}$ Detection and CharacterizationIEEE Transactions on Applied Superconductivity, 2009
- SQUIDs for Magnetic Resonance Imaging at Ultra-low Magnetic FieldPIERS Online, 2009
- Microtesla MRI of the human brain combined with MEGJournal of Magnetic Resonance, 2008
- A 75-ch SQUID Biomagnetometer System for Human Cervical Spinal Cord Evoked FieldIEEE Transactions on Applied Superconductivity, 2007
- Calculated signal-to-noise ratio of MRI detected with SQUIDs and Faraday detectors in fields from 10μT to 1.5TJournal of Magnetic Resonance, 2007
- Induction coil sensors—a reviewMeasurement Science and Technology, 2007
- Ultra-low field NMR measurements of liquids and gases with short relaxation timesJournal of Magnetic Resonance, 2006
- Liquid-State NMR and Scalar Couplings in Microtesla Magnetic FieldsScience, 2002
- Novel approaches to low‐cost MRIMagnetic Resonance in Medicine, 1993