Do Currently Available Blood Glucose Monitors Meet Regulatory Standards? 1-Day Public Meeting in Arlington, Virginia
Open Access
- 1 July 2013
- journal article
- abstracts
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 7 (4) , 1071-1083
Abstract
Blood glucose monitors (BGMs) are approved by regulatory agencies based on their performance during strict testing conducted by their manufacturers. However, after approval, there is uncertainty whether BGMs maintain the accuracy levels that were achieved in the initial data. The availability of inaccurate BGM systems pose a public health problem because their readings serve as a basis for treatment decisions that can be incorrect. Several articles have concluded that BGMs in the marketplace may not consistently provide accurate results in accordance with the regulatory standards that led to approval. To address this growing concern, Diabetes Technology Society organized and conducted a 1-day public meeting on May 21, 2013, in Arlington, VA, presided by its president, David Klonoff, M.D., FACP, Fellow AIMBE, to determine whether BGMs on the market meet regulatory standards. The meeting consisted of four sessions in which Food and Drug Administration diabetes experts as well as leading academic clinicians and clinical chemists participated: (1) How is BGM performance determined? (2) Do approved BGMs perform according to International Organization for Standardization standards? (3) How do approved BGMs perform when used by patients and health care professionals? (4) What could be the consequence of poor BGM performance?Keywords
This publication has 14 references indexed in Scilit:
- Assessing the Quality of Publications Evaluating the Accuracy of Blood Glucose Monitoring SystemsDiabetes Technology & Therapeutics, 2013
- Effects of Dynamic Temperature and Humidity Stresses on Point-of-Care Glucose Testing for Disaster CareDisaster Medicine and Public Health Preparedness, 2012
- A Thermo-Modulating Container for Transport and Storage of Glucose Meters in a Cold Weather EnvironmentPoint of Care: The Journal of Near-Patient Testing & Technology, 2012
- Devices and desiresBMJ, 2012
- Accuracy Evaluation of Five Blood Glucose Monitoring Systems Obtained from the Pharmacy: A European Multicenter Study with 453 SubjectsDiabetes Technology & Therapeutics, 2012
- Clinical assessment of the accuracy of blood glucose measurement devicesCurrent Medical Research and Opinion, 2012
- When the Earth Trembles in the Americas: The Experience of Haiti and Chile 2010Nephron Clinical Practice, 2010
- System Accuracy Evaluation of 27 Blood Glucose Monitoring Systems According to DIN EN ISO 15197Diabetes Technology & Therapeutics, 2010
- Mass Medical Evacuation: Hurricane Katrina and Nursing Experiences at the New Orleans AirportDisaster Management & Response, 2007
- Between-Lot Variation in External Quality Assessment of Glucose: Clinical Importance and Effect on Participant Performance EvaluationClinical Chemistry, 2005