Independent Suture Tape Reinforcement of Tripled Smaller‐Diameter and Quadrupled Grafts for Anterior Cruciate Ligament Reconstruction With Tibial Screw Fixation: A Biomechanical Full Construct Model
- 31 December 2019
- journal article
- research article
- Published by Wiley in Arthroscopy
- Vol. 36 (2) , 481-489
Abstract
Purpose: To compare the effect of independent suture tape reinforcement on the dynamic elongation and stiffness behavior as well as ultimate strength of tripled smaller‐diameter and quadrupled soft‐tissue grafts for anterior cruciate ligament reconstruction (ACLR) with tibial screw fixation in a biomechanical in vitro study. Methods: Tripled smaller‐diameter (8 mm) and quadrupled (9 mm) bovine tendon grafts with and without suture tape reinforcement (n = 8 in each group) were tested using femoral suspensory and tibial interference screw fixation. The suture tape was femoral sided and fixed independent from the graft by passing it through the suspensory button and securing the 2 open tibial strands with a secondary interference screw. Dynamic testing was performed in position and force control at 250 N and 400 N, followed by pull to failure with the mode of failure noted. Dynamic elongation, stiffness, and ultimate strength were analyzed. Results: Tripled constructs showed a significantly worse structural performance than quadrupled constructs at higher loads. Reinforcement of tripled and quadrupled grafts substantially decreased total elongation by 56% (4.54 ± 0.75 mm vs 2.01 ± 0.50 mm, P < .001) and 39% (3.25 ± 0.49 mm vs 1.98 ± 0.51 mm, P < .001), respectively, by significantly increasing dynamic stiffness. No statistical significance was found between the reinforced groups. Failure loads of reinforced tripled (1,074 ± 148 N vs 829 ± 100 N, P = .003) and quadrupled (1,125 ± 157 N vs 939 ± 76 N, P = .023) grafts were also significantly improved. Conclusions: Independent reinforcement of soft‐tissue grafts with suture tape strengthened the performance especially of tripled smaller‐diameter grafts for ACLR with tibial screw fixation by significantly improving dynamic elongation at increased stiffness and ultimate strength. Quadrupled reinforced grafts showed no over‐constraining and structurally behaved similarly to tripled grafts with reinforcement. Clinical Relevance: Independent reinforcement for ACLR may provide an option for protecting autografts or allografts against irreversible lengthening during the maturation and remodeling phases of healing.Keywords
Funding Information
- Arthrex
This publication has 28 references indexed in Scilit:
- Posterior Single‐Incision Semitendinosus Harvest for a Quadrupled Anterior Cruciate Ligament Graft Construct: Determination of Graft Length and Diameter Based on Patient Sex, Height, Weight, and Body Mass IndexArthroscopy, 2014
- Knee Medial Collateral Ligament and Posteromedial Corner Anatomic Repair With Internal BracingArthroscopy Techniques, 2014
- Hamstring Autograft Size Can Be Predicted and Is a Potential Risk Factor for Anterior Cruciate Ligament Reconstruction FailureArthroscopy, 2014
- Biomechanical Comparison of Interference Screws and Combination Screw and Sheath Devices for Soft Tissue Anterior Cruciate Ligament Reconstruction on the Tibial SideThe American Journal of Sports Medicine, 2013
- Graft Tensioning in Anterior Cruciate Ligament Reconstruction: A Systematic Review of Randomized Controlled TrialsArthroscopy, 2008
- Hamstring Graft Size PredictionThe American Journal of Sports Medicine, 2008
- In vivo kinematics of the ACL during weight‐bearing knee flexionJournal of Orthopaedic Research, 2005
- Pattern of anterior cruciate ligament force in normal walkingJournal of Biomechanics, 2004
- Interspecies Differences in Bone Composition, Density, and Quality: Potential Implications for in Vivo Bone Research*Endocrinology, 1998
- Tensile properties of the human femur-anterior cruciate ligament-tibia complexThe American Journal of Sports Medicine, 1991