Abstract
The purpose of this study was to determine whether dynamic elastance EAdyn derived from echocardiographic measurements of stroke volume variations can predict the success of a one-step decrease of norepinephrine dose. In this prospective single-center study, 39 patients with vasoplegic syndrome treated with norepinephrine and for whom the attending physician had decided to decrease norepinephrine dose and monitored by thermodilution were analyzed. EAdyn is the ratio of pulse pressure variation to stroke volume variation and was calculated from echocardiography stroke volume variations and from transpulmonary thermodilution. Pulse pressure variation was obtained from invasive arterial monitoring. Responders were defined by a decrease in mean arterial pressure (MAP) > 10% following norepinephrine decrease. The median decrease in norepinephrine was of 0.04 [0.03–0.05] µg kg−1 min−1. Twelve patients (31%) were classified as pressure responders with a median decrease in MAP of 13% [12–15%]. EAdyn was lower in pressure responders (0.40 [0.24–0.57] vs 0.95 [0.77–1.09], p < 0.01). EAdyn was able to discriminate between pressure responders and non-responders with an area under the curve of 0.86 (CI95% [0.71 to1.0], p < 0.05). The optimal cut-off was 0.8. EAdyn calculated from the echocardiographic estimation of the stroke volume variation and the invasive arterial pulse pressure variation can be used to discriminate pressure response to norepinephrine weaning. Agreement between EAdyn calculated from echocardiography and thermodilution was poor. Echocardiographic EAdyn might be used at bedside to optimize hemodynamic treatment.Keywords
This publication has 23 references indexed in Scilit:
- Point-of-care ultrasound in intensive care units: assessment of 1073 procedures in a multicentric, prospective, observational studyIntensive Care Medicine, 2015
- Management of cardiogenic shockEuropean Heart Journal, 2015
- Recommandations sur la réanimation du choc hémorragiqueAnesthésie & Réanimation, 2015
- Dynamic arterial elastance predicts mean arterial pressure decrease associated with decreasing norepinephrine dosage in septic shockCritical Care, 2015
- Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopyBritish Journal of Anaesthesia, 2013
- Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgeryBritish Journal of Anaesthesia, 2012
- Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patientsCritical Care, 2011
- Comparison of stroke volume (SV) and stroke volume respiratory variation (SVV) measured by the axillary artery pulse-contour method and by aortic Doppler echocardiography in patients undergoing aortic surgeryBritish Journal of Anaesthesia, 2006
- Noninvasive single-beat determination of left ventricular end-systolic elastance in humansJACC, 2001
- Optimal arterial resistance for the maximal stroke work studied in isolated canine left ventricle.Circulation Research, 1985