A comparison of physical activity from Actigraph GT3X+ accelerometers worn on the dominant and non‐dominant wrist
- 30 July 2018
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 39 (1) , 51-56
Abstract
Summary: The purpose of this study was to evaluate the agreement between several activity measures using raw acceleration data from accelerometers worn concurrently on the dominant and non‐dominant wrist. Fifty‐five adults (31·9 ± 9·7 years, 26 males) wore two ActiGraph GT3X+ monitors continuously for 1 day, one on their non‐dominant wrist and the other on their dominant wrist. Paired t‐tests were undertaken with sequential Holm‐Bonferroni corrections to compare wear time, moderate‐vigorous physical activity (MVPA), time spent in 10‐min bouts of MVPA (MVPA10 min) and the average magnitude of dynamic wrist acceleration (ENMO). Level of agreement between outcome variables from the wrists was examined using intraclass correlation coefficients (ICC, single measures, absolute agreement) with 95% confidence intervals and limits of agreement (LoA). Time spent across acceleration levels in 40 mg resolution were also examined. There were no significant differences between the non‐dominant and dominant wrist for ENMO, wear time, MVPA or MVPA10 min. Agreement between wrists was strong for most outcomes (ICC ≥0·92) including wear time, ENMO, MVPA, MVPA10 min and the distribution of time across acceleration levels. Agreement was strong in the low acceleration bands (ICC = 0·970 and 0·922) with a mean bias of 3·08 min (LoA −55·18 to 61·34) and −5·43 (LoA −43·47 to 32·62). In summary, ENMO, MVPA, MVPA10 min, wear time and the distribution of time across acceleration levels compared well at the group level. The LOA from the two lowest acceleration levels suggest further work over a longer monitoring period is needed to determine whether outputs from each wrist are comparable.Keywords
Funding Information
- University of the West of Scotland
This publication has 31 references indexed in Scilit:
- Lab-based validation of different data processing methods for wrist-worn ActiGraph accelerometers in young adultsPhysiological Measurement, 2017
- Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank StudyPLOS ONE, 2017
- Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted AccelerometersMedicine & Science in Sports & Exercise, 2016
- Physical activity using wrist‐worn accelerometers: comparison of dominant and non‐dominant wristClinical Physiology and Functional Imaging, 2016
- Understanding Bland Altman analysisBiochemia Medica, 2015
- 150 minutes of vigorous physical activity per week predicts survival and successful ageing: a population-based 11-year longitudinal study of 12 201 older Australian menBritish Journal of Sports Medicine, 2013
- Sedentary Behavior and Physical Activity Are Independent Predictors of Successful Aging in Middle-Aged and Older AdultsJournal of Aging Research, 2012
- Estimation of Daily Energy Expenditure in Pregnant and Non-Pregnant Women Using a Wrist-Worn Tri-Axial AccelerometerPLOS ONE, 2011
- Validation of the GENEA AccelerometerMedicine & Science in Sports & Exercise, 2011
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986