A dosimetric study on the use of 3D‐printed customized boluses in photon therapy: A hydrogel and silica gel study
Authors:
Open Access
- 7 November 2018
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (1) , 348-355
Abstract
Purpose: The aim of the study was to compare the dose differences between two kinds of materials (silica gel and hydrogel) used to prepare boluses based on three‐dimensional (3D) printing technologies and commercial bolus in head phantoms simulating nose, ear, and parotid gland radiotherapy.Methods and materials: We used 3D printing technology to make silica gel and hydrogel boluses. To evaluate the clinical feasibility, intensity modulated radiation therapy (IMRT) plans were created for head phantoms that were bolus‐free or had a commercial bolus, a silica gel bolus, or a hydrogel bolus. Dosimetry differences were compared in simulating nose, ear, and parotid gland radiotherapy separately.Results: The air gaps were smaller in the silica gel and hydrogel bolus than the commercial one. In nose plans, it was shown that the V95% (relative volume that is covered by at least 95% of the prescription dose) of the silica gel (99.86%) and hydrogel (99.95%) bolus were better than the commercial one (98.39%) and bolus‐free (87.52%). Similarly, the homogeneity index (HI) and conformity index (CI) of the silica gel (0.06; 0.79) and hydrogel (0.058; 0.80) bolus were better than the commercial one (0.094; 0.72) and bolus‐free (0.59; 0.53). The parameters of results (HI, CI, V95%) were also better in 3D printing boluses than in the commercial bolus or without bolus in ear and parotid plans.Conclusions: Silica gel and hydrogel boluses were not only good for fit and a high level of comfort and repeatability, but also had better parameters in IMRT plans. They could replace the commercial bolus for clinical use.Keywords
Funding Information
- Suzhou Science and Technology Development Program, China (SS201642, SZS201509)
- Jiangsu Medical Innovation Team, China (CXDT-37)
- Suzhou Clinical Medical Center Construction Project, China (Szzxj201503)
This publication has 25 references indexed in Scilit:
- Efficacy of patient-specific bolus created using three-dimensional printing technique in photon radiotherapyPhysica Medica, 2017
- 3D-printing techniques in a medical setting: a systematic literature reviewBioMedical Engineering OnLine, 2016
- Single-fraction flattening filter–free volumetric modulated arc therapy for lung cancer: Dosimetric results and comparison with flattened beams techniqueMedical Dosimetry, 2016
- Potential of 3D printing technologies for fabrication of electron bolus and proton compensatorsJournal of Applied Clinical Medical Physics, 2015
- Design and production of 3D printed bolus for electron radiation therapyJournal of Applied Clinical Medical Physics, 2014
- On bolus for megavoltage photon and electron radiation therapyMedical Dosimetry, 2013
- Accuracy of pencil‐beam redefinition algorithm dose calculations in patient‐like cylindrical phantoms for bolus electron conformal therapyMedical Physics, 2013
- Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapyMedical Physics, 2013
- An investigation of central axis depth dose distribution perturbation due to an air gap between patient and bolus for electron beamsAustralasian Physics & Engineering Sciences in Medicine, 2007
- Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapyRadiation Measurements, 2000