The Barnes-Jarvis flicker-noise generator is usually initialized by setting its filter variables to zero. Call the resulting output yp One can also initialize the filter so that the output is a stationary process ys. Let these outputs represent clock-frequency deviations. Then, although ys and yp cannot be distinguished by their two-sample variances, the mean square time-interval error of ys, exceeds that of yp by a factor of the order log t.