Elimination of Drifts in Long-Duration Monitoring for Apnea-Hypopnea of Human Respiration
Open Access
Abstract
This paper reports a methodology to eliminate an uncertain baseline drift in respiratory monitoring using a thermal airflow sensor exposed in a high humidity environment. Human respiratory airflow usually contains a large amount of moisture (relative humidity, RH > 85%). Water vapors in breathing air condense gradually on the surface of the sensor so as to form a thin water film that leads to a significant sensor drift in long-duration respiratory monitoring. The water film is formed by a combination of condensation and evaporation, and therefore the behavior of the humidity drift is complicated. Fortunately, the exhale and inhale responses of the sensor exhibit distinguishing features that are different from the humidity drift. Using a wavelet analysis method, we removed the baseline drift of the sensor and successfully recovered the respiratory waveform. Finally, we extracted apnea-hypopnea events from the respiratory signals monitored in whole-night sleeps of patients and compared them with golden standard polysomnography (PSG) results.Keywords
Funding Information
- the National High-tech Program “863” of China (2012AA02A604)
This publication has 20 references indexed in Scilit:
- Gas Recognition under Sensor Drift by Using Deep LearningInternational Journal of Intelligent Systems, 2015
- Flow measurement in mechanical ventilation: A reviewMedical Engineering & Physics, 2015
- Cognitive complaints in obstructive sleep apneaSleep Medicine Reviews, 2015
- Pulse oximetry-derived respiratory rate in general care floor patientsJournal of Clinical Monitoring and Computing, 2014
- Overnight Polysomnography versus Respiratory Polygraphy in the Diagnosis of Pediatric Obstructive Sleep ApneaSLEEP, 2014
- An orifice meter for bidirectional air flow measurements: Influence of gas thermo-hygrometric content on static response and bidirectionalityFlow Measurement and Instrumentation, 2013
- Sensors for Breath Testing: From Nanomaterials to Comprehensive Disease DetectionAccounts of Chemical Research, 2013
- A new algorithm for the compression of ECG signals based on mother wavelet parameterization and best-threshold levels selectionDigital Signal Processing, 2013
- A robust fetal ECG detection method for abdominal recordingsPhysiological Measurement, 2007
- Correction factors for oxygen and flow-rate effects on neonatal Fleisch and Lilly pneumotachometersPediatric Critical Care Medicine, 2003