An Approach for Out-of-Step Protection Based on Swing Center Voltage Estimation and Analytic Geometry Parameters
- 14 February 2020
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (3) , 2402-2408
Abstract
Out-of-step protection has been widely studied, and it remains an important topic in the field. Given the crucial modernization of the power systems and the evolution of protective relaying, it is crucial to merge from traditionally fixed parameters to novel approaches that allow flexibility and possible time-domain protection. This paper presents a new methodology to implement an out-of-step protection algorithm through the geometrical understanding of a power system oscillation using Clarke's transformation. The study is an extension of a virtual relay solution previously developed and improves the Swing Center Voltage solution in the α-β plane with enhanced selectivity. The result brings a functional virtual relay capable of detecting and reacting under stable and unstable power swing events through playback techniques. The contribution of this study relies on the application of the time-domain approach to improving the function ANSI 78 as an extension of ongoing research on virtualization of power system protection and realtime prototyping.Keywords
Funding Information
- Administrative Department of Science, Technology, and Innovation of Colombia, COLCIENCIAS (681, 712)
This publication has 28 references indexed in Scilit:
- Adaptive concentric power swing blockerProtection and Control of Modern Power Systems, 2016
- Out-of-Step Protection Based on Equal Area CriterionIEEE Transactions on Power Systems, 2016
- A New Method for Blocking Third-Zone Distance Relays During Stable Power SwingsIEEE Transactions on Power Delivery, 2016
- New support vector machine‐based digital relaying scheme for discrimination between power swing and faultIET Generation, Transmission & Distribution, 2014
- Comparative evaluation of out of step detection schemes for distance relays2012
- Do system impedances really affect power swings — Applying power swing protection elements without complex system studies2012
- A novel power swing blocking scheme using adaptive neuro-fuzzy inference systemElectric Power Systems Research, 2008
- The Instantaneous Power Theory2006
- Zero-setting power-swing blocking protection2005
- A predictive out-of-step protection system based on observation of the phase difference between substationsIEEE Transactions on Power Delivery, 1990