Determination of haloacetic acids in water using solid‐phase extraction/microchip capillary electrophoresis with capacitively coupled contactless conductivity detection
Authors:
- 23 July 2010
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 31 (15) , 2602-2607
Abstract
Haloacetic acids (HAAs) were determined by a fast and simple analysis method based on microchip electrophoresis and capacitively coupled contactless conductivity detection (C4D). Two chlorinated acetic acids, dichloroacetic acid (DCAA) and TCA were detected in swimming pool water. Different BGEs were tested, and sodium carbonate was selected as BGE for the separation and detection in the reported experiments. Additionally, pH values and concentrations of carbonate buffer were optimized. The response times for the two analytes were less than 3 min; the lowest detected concentrations for TCA and DCAA after extraction and cleanup were 38 and 62 μg/L and the RSDs for the migration times were 1.9 and 2.2%. TCA and DCAA were identified swimming pool water samples at concentrations ranging from 391 to 1058 μg/L. In combination with a SPE‐based concentration and cleanup procedure, this miniaturized system shows the potential for development as an on‐site monitoring method for chlorinated acetic acids found in swimming pool water or other suspected water systems.Keywords
This publication has 36 references indexed in Scilit:
- Yield of trihalomethanes and haloacetic acids upon chlorinating algal cells, and its prediction via algal cellular biochemical compositionWater Research, 2008
- Measurement of Nitrogen Mustard Degradation Products by Poly(dimethylsiloxane) Microchip Electrophoresis with Contactless Conductivity DetectionElectroanalysis, 2008
- A thin cover glass chip for contactless conductivity detection in microchip capillary electrophoresisTalanta, 2007
- FTIR evaluation of functional groups involved in the formation of haloacetic acids during the chlorination of raw waterJournal of Hazardous Materials, 2006
- Pulsed amperometric detection with poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips for the determination of EPA priority pollutantsThe Analyst, 2005
- Capillary and microchip electrophoresis of basic drugs with contactless conductivity detectionElectrophoresis, 2004
- Using ion chromatography to monitor haloacetic acids in drinking water: a review of current technologiesJournal of Chromatography A, 2004
- Haloacetic acids in the aquatic environment. Part I: macrophyte toxicityEnvironmental Pollution, 2004
- Formation of haloacetic acids during monochloraminationWater Research, 2004
- Determination of haloacetic acids in water by acidic methanol esterification–GC–ECD methodWater Research, 2002