Abstract
The inverter nonlinearity and spatial flux harmonics inevitably result in the back electromotive force (BEMF) harmonics in permanent magnet synchronous motor (PMSM), which deteriorates the performance of the model-based sensorless control. To settle the problem, this article proposes an enhanced adaptive disturbance observer by reconstructing the observer structure based on the pre-designed enhanced complex coefficient filter (ECCF). An ECCF with specific harmonic filtering capability based on conventional complex coefficient filter and multi-frequency suppression module is pre-constructed. Based on the reverse design method, the structure of the conventional disturbance observer is reconstructed into the desired ECCF structure. Multi-harmonics can be suppressed without cascading additional filtering networks after the conventional BEMF observers. The sensorless control algorithm studied is verified by the comparative experiments on a 1 kW PMSM platform.