Dexamethasone-Enhanced Microdialysis and Penetration Injury
Open Access
- 8 December 2020
- journal article
- review article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8
Abstract
Microdialysis probes, electrochemical microsensors, and neural prosthetics are often used forin vivomonitoring, but these are invasive devices that are implanted directly into brain tissue. Although the selectivity, sensitivity, and temporal resolution of these devices have been characterized in detail, less attention has been paid to the impact of the trauma they inflict on the tissue or the effect of any such trauma on the outcome of the measurements they are used to perform. Factors affecting brain tissue reaction to the implanted devices include: the mechanical trauma during insertion, the foreign body response, implantation method, and physical properties of the device (size, shape, and surface characteristics. Modulation of the immune response is an important step toward making these devices with reliable long-term performance. Local release of anti-inflammatory agents such as dexamethasone (DEX) are often used to mitigate the foreign body response. In this article microdialysis is used to locally deliver DEX to the surrounding brain tissue. This work discusses the immune response resulting from microdialysis probe implantation. We briefly review the principles of microdialysis and the applications of DEX with microdialysis in (i) neuronal devices, (ii) dopamine and fast scan cyclic voltammetry, (iii) the attenuation of microglial cells, (iv) macrophage polarization states, and (v) spreading depolarizations. The difficulties and complexities in these applications are herein discussed.Keywords
This publication has 155 references indexed in Scilit:
- Carbon nanotube nanoreservior for controlled release of anti-inflammatory dexamethasoneBiomaterials, 2011
- Collection of nanoliter microdialysate fractions in plugs for off-line in vivo chemical monitoring with up to 2 s temporal resolutionJournal of Neuroscience Methods, 2010
- Recurrent spreading depolarizations after subarachnoid hemorrhage decreases oxygen availability in human cerebral cortexAnnals of Neurology, 2010
- Comparison of the brain penetration injury associated with microdialysis and voltammetryJournal of Neuroscience Methods, 2009
- Review of recent advances in analytical techniques for the determination of neurotransmittersAnalytica Chimica Acta, 2009
- Impact of microdialysis probes on vasculature and dopamine in the rat striatum: A combined fluorescence and voltammetric studyJournal of Neuroscience Methods, 2008
- Application of long-term microdialysis in circadian rhythm researchPharmacology Biochemistry and Behavior, 2007
- The effect of covalently immobilized rhIL-1ra-ELP fusion protein on the inflammatory profile of LPS-stimulated human monocytesBiomaterials, 2007
- Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probesBrain Research, 2007
- Overview of MicrodialysisCurrent Protocols in Neuroscience, 1997