Optimization of Left Ventricle Pace Maker Location Using Echo-Based Fluid-Structure Interaction Models
Open Access
- 17 February 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 843421
Abstract
Introduction: Cardiac pacing has been an effective treatment in the management of patients with bradyarrhythmia and tachyarrhythmia. Different pacemaker location has different responses, and pacemaker effectiveness to each individual can also be different. A novel image-based ventricle animal modeling approach was proposed to optimize ventricular pacemaker site for better cardiac outcome.Method: One health female adult pig (weight 42.5 kg) was used to make a pacing animal model with different ventricle pacing locations. Ventricle surface electric signal, blood pressure and echo image were acquired 15 min after the pacemaker was implanted. Echo-based left ventricle fluid-structure interaction models were constructed to perform ventricle function analysis and investigate impact of pacemaker location on cardiac outcome. With the measured electric signal map from the pig associated with the actual pacemaker site, electric potential conduction of myocardium was modeled by material stiffening and softening in our model, with stiffening simulating contraction and softening simulating relaxation. Ventricle model without pacemaker (NP model) and three ventricle models with the following pacemaker locations were simulated: right ventricular apex (RVA model), posterior interventricular septum (PIVS model) and right ventricular outflow tract (RVOT model). Since higher peak flow velocity, flow shear stress (FSS), ventricle stress and strain are linked to better cardiac function, those data were collected for model comparisons.Results: At the peak of filling, velocity magnitude, FSS, stress and strain for RVOT and PIVS models were 13%, 45%, 18%, 13% and 5%, 30%, 10%, 5% higher than NP model, respectively. At the peak of ejection, velocity magnitude, FSS, stress and strain for RVOT and PIVS models were 50%, 44%, 54%, 59% and 23%, 36%, 39%, 53% higher than NP model, respectively. RVA model had lower velocity, FSS, stress and strain than NP model. RVOT model had higher peak flow velocity and stress/strain than PIVS model. It indicated RVOT pacemaker site may be the best location.Conclusion: This preliminary study indicated that RVOT model had the best performance among the four models compared. This modeling approach could be used as “virtual surgery” to try various pacemaker locations and avoid risky and dangerous surgical experiments on real patients.Keywords
This publication has 37 references indexed in Scilit:
- Focus on right ventricular outflow tract septal pacingArchives of Cardiovascular Diseases, 2013
- Circumferential myocardial contraction patterns in patients with idiopathic frequent premature ventricular complexes from the right ventricular outflow tractInternational Journal of Cardiology, 2011
- The Right Ventricular Septum Presents the Optimum Site for Maximal Electrical Separation During Left Ventricular PacingJournal of Cardiovascular Electrophysiology, 2011
- Multi-physics MRI-based two-layer fluid–structure interaction anisotropic models of human right and left ventricles with different patch materials: Cardiac function assessment and mechanical stress analysisComputers & Structures, 2011
- Image-based patient-specific ventricle models with fluid–structure interaction for cardiac function assessment and surgical design optimizationProgress in Pediatric Cardiology, 2010
- Advances in Cardiac Pacing: Beyond the Transvenous Right Ventricular Apical LeadCardiovascular Therapeutics, 2010
- Distribution of Electromechanical Delay in the Heart: Insights from a Three-Dimensional Electromechanical ModelBiophysical Journal, 2010
- The Effects of Right Ventricular Apical Pacing on Ventricular Function and DyssynchronyJACC, 2009
- Alternate Site Pacing in Patients at Risk for Heart FailureAngiology, 2008
- Biomechanical Dynamics of the Heart with MRIAnnual Review of Biomedical Engineering, 2002