Cell Culture on Low-Fluorescence and High-Resolution Photoresist
Open Access
- 4 June 2020
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 11 (6) , 571
Abstract
2D and 3D topographic cues made of photoresist, a polymer, are used for cell culture and cell analysis. Photoresists used for cell analysis provide the surface conditions necessary for proper cell growth, along with patterning properties of a wide range and high precision, and low auto-fluorescence that does not affect fluorescence imaging. In this study, we developed a thick negative photoresist SJI-001 possessing the aforementioned properties. We evaluated the surface conditions of SJI-001 affecting cell culture. First, we studied the wettability of SJI-001, which was changed by plasma treatment, conducted as a pretreatment on a plastic substrate before cell seeding. SJI-001 was more chemically stable than SU-8 used for fabricating the micro-electromechanical systems (MEMS). Furthermore, the doubling time and adhesion rate of adherent HeLa cells cultured on untreated SJI-001 were 25.2 h and 74%, respectively, thus indicating its suitability for cell culture over SU-8. In addition, we fabricated a cell culture plate with a 3D lattice structure, three micrometers in size, using SJI-001. HeLa cells seeded on this plate remained attached over five days. Therefore, SJI-001 exhibits surface conditions suitable for cell culture and has several bioapplications including microstructures and cell chips for cell culture and cell analysis.Keywords
Funding Information
- Japan Society for the Promotion of Science (16J12039, JP17H03196)
- Japan Science and Technology Agency (JPMJPR15R3, JPMJCR19Q2)
This publication has 39 references indexed in Scilit:
- Polydimethylsiloxane (PDMS) Sub-Micron Traps for Single-Cell Analysis of BacteriaMicromachines, 2013
- On-chip nanohole array based sensing: a reviewLab on a Chip, 2013
- On chip porous polymer membranes for integration of gastrointestinal tract epithelium with microfluidic ‘body-on-a-chip’ devicesBiomedical Microdevices, 2012
- Accurate Detection of Carcinoma Cells by Use of a Cell Microarray ChipPLOS ONE, 2012
- Micro Total Bioassay System for Ingested Substances: Assessment of Intestinal Absorption, Hepatic Metabolism, and BioactivityAnalytical Chemistry, 2010
- Cell proliferation assays on plasma activated SU-8Microelectronic Engineering, 2008
- Enhanced cell attachment using a novel cell culture surface presenting functional domains from extracellular matrix proteinsCytotechnology, 2008
- Single-Cell Microarray for Analyzing Cellular ResponseAnalytical Chemistry, 2005
- SU-8: a low-cost negative resist for MEMSJournal of Micromechanics and Microengineering, 1997
- High-aspect-ratio photolithography for MEMS applicationsJournal of Microelectromechanical Systems, 1995