Investigation of off-board DPI method
Authors:
- 1 May 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21627673,p. 643-646
Abstract
An off-board direct RF power injection (DPI) method using a probe is proposed to investigate the IC immunity. The details of the measurement setup are outlined in this works. We also reviewed the conventional DPI method in addition to a discussion on the limitation of the test printed circuit board. The 3 dB bandwidth of this proposed probe is confirmed. A low dropout regulator (LDO) is used to compare the performance of the on-board injection network and the proposed scheme. The experimental result shows that the maximum deviation of the immunity level is less than 1 dB between the conventional and the proposed method.Keywords
This publication has 3 references indexed in Scilit:
- Design of a 20 GHz DPI method for SOIC82012
- The Electromagnetic Compatibility of Integrated Circuits—Past, Present, and FutureIEEE Transactions on Electromagnetic Compatibility, 2009
- Efficiency of Embedded On-Chip EMI Protections to Continuous Harmonic and Fast Transient Pulses with Respect to Substrate Injection2007