Elemental speciation with liquid chromatography–inductively coupled plasma isotope dilution mass spectrometry
Authors:
- Klaus G. HeumannKHKlaus G. Heumann
- L. RottmannLRL. Rottmann
- J. VoglJ. Vogl
- 1 January 1994
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 9 (12) , 1351-1355
Abstract
For the determination of elemental species, which normally exist at low concentrations in the environment, coupling of liquid chromatographic systems with inductively coupled plasma mass spectrometry (ICP-MS) is a powerful method with respect to detection limit. However, accurate results are still a problem in trace analyses but can be obtained by the application of isotope dilution mass spectrometry (IDMS). The developed LC–ICP-IDMS system consists of a high-performance liquid chromatography pump, a sample injection valve, a separation column (different types of chromatographic separation systems, e.g., ion or size-exclusion chromatography, were used depending on the separation problem), a non-destructive detector (e.g. a UV detector) for simultaneous determination of organic substances, and an element-specific ICP mass spectrometer. Isotope dilution is carried out by adding an isotopically enriched species-specific spike solution to the sample prior to the separation step in the case of the determination of well-defined species, or by continuous on-line introduction of a species-unspecific spike solution in the case of species with unknown composition and structure. The species-specific spiking method is demonstrated for the determination of iodide and iodate in mineral water using an ion chromatographic separation column. For example, iodate concentrations in the range of 0.5–20 ng ml–1 could be determined with relative standard deviations of about 2%. The species-unspecific spiking mode is used to determined heavy metal complexes with humic substances at a level of about 1 ng ml–1 as well as organo-iodine species in the concentration range 0.7–1.4 ng ml–1 in natural water systems. The accuracy of speciation could be verified by comparing the total element concentration with the sum of the different elemental species.Keywords
This publication has 10 references indexed in Scilit:
- Development of an on-line isotope dilution technique with HPLC/ICP-MS for the accurate determination of elemental speciesAnalytical and Bioanalytical Chemistry, 1994
- Determination of copper, molybdenum and selenium in biological reference materials by inductively coupled plasma mass spectrometryAnalytical and Bioanalytical Chemistry, 1993
- Separation of seven arsenic compounds by high-performance liquid chromatography with on-line detection by hydrogen–argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1992
- Lead speciation by gradient high-performance liquid chromatography with inductively coupled plasma mass spectrometric detectionJournal of Analytical Atomic Spectrometry, 1992
- Determination of lead and other trace element species in blood by size exclusion chromatography and inductively coupled plasma/mass spectrometryAnalytical Chemistry, 1991
- Metalloprotein separation and analysis by directly coupled size exclusion high-performance liquid chromatography inductively coupled plasma mass spectroscopyAnalytical Biochemistry, 1990
- Applications of ICP-MS in marine analytical chemistryAnalytical and Bioanalytical Chemistry, 1990
- On-line isotope dilution and sample dilution by flow injection and inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1990
- Application of high-performance liquid chromatography-inductively coupled plasma mass spectrometry to the investigation of cadmium speciation in pig kidney following cooking and in vitro gastro-intestinal digestionThe Analyst, 1989
- Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometryAnalytical Chemistry, 1987