Suitability of Filofocon A and PMMA for experimental models in excimer laser ablation refractive surgery
- 3 December 2008
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 16 (25) , 20955-20967
Abstract
Experimental corneal models in plastic (in PMMA, and more recently in Filofocon A, a contact lens material) have been proposed recently to overcome some of the limitations of the theoretical approaches aiming at improving the predictability of corneal reshaping by laser ablation. These models have also been proposed for accurate assessment of corneal laser ablation patterns. In this study Filofocon A and PMMA optical and ablation properties were studied using an experimental excimer laser set-up. The effective absorption coefficient and the ablation thresholds of these materials were obtained as a function of the number of pulses. Both materials follow a Beer-Lambert law in the range of fluences used in refractive surgery, and the number of incubation pulses is less than 4 (PMMA) and 2 (Filofocon A) above 140 mJ/cm2. We found that above 40 pulses for Filofocon A and 70 pulses for PMMA, ablation threshold and effective absorption coefficients can be considered constant (Fth=90 mJ/cm2 and αeff=36000 cm-1, for Filofocon A, and Fth=67 mJ/cm2 and αeff=52000 cm-1 for PMMA, respectively). The absence of ablation artifacts (central islands), a lower number of incubation pulses, a lower pulse-number dependence of the ablation threshold, and a good correspondence between αeff and the absorption coefficient α estimated from spectroscopic measurements make Filofocon A a more appropriate material than PMMA for experimental models in refractive surgery and for calibration of clinical lasers.Keywords
This publication has 33 references indexed in Scilit:
- Biomechanics and wound healing in the corneaExperimental Eye Research, 2006
- Theory concerning the ablation of corneal tissue with large-area, 193-nm excimer laser beamsJournal of Biomedical Optics, 2006
- Wavefront-optimized ablation profilesJournal of Cataract & Refractive Surgery, 2004
- Laser‐assisted fabrication of monomode polymer waveguides and their optical characterizationMaterialwissenschaft und Werkstofftechnik, 2003
- Optimal corneal ablation for eyes with arbitrary Hartmann–Shack aberrationsJournal of the Optical Society of America A, 1998
- Corneal-tissue absorption coefficients for 193- and 213-nm ultraviolet radiationApplied Optics, 1996
- Excimer laser corneal ablation: Absence of a significant “incubation” effectLasers in Surgery and Medicine, 1991
- Low temperature UV laser etching of PMMA: On the mechanism of ablative photodecomposition (APD)Journal of Polymer Science Part C: Polymer Letters, 1986
- Photochemical cleavage of a polymeric solid: details of the ultraviolet laser ablation of poly(methyl methacrylate) at 193 nm and 248 nmMacromolecules, 1986
- Ablative photodecomposition of polymer films by pulsed far‐ultraviolet (193 nm) laser radiation: Dependence of etch depth on experimental conditionsJournal of Polymer Science: Polymer Chemistry Edition, 1984