Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for 125I prostate implants
Authors:
Open Access
- 4 August 2022
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 49 (9) , 6195-6208
Abstract
Purpose: Monte Carlo (MC) simulation studies, aimed at evaluating the magnitude of tissue heterogeneity in 125I prostate permanent seed implant brachytherapy (BT), customarily use clinical post‐implant CT images to generate a virtual representation of a realistic patient model (virtual patient model). Metallic artifact reduction (MAR) techniques and tissue assignment schemes (TAS) are implemented on the post‐implant CT images to mollify metallic artifacts due to BT seeds and to assign tissue types to the voxels corresponding to the bright seed spots and streaking artifacts, respectively. The objective of this study is to assess the combined influence of MAR and TAS on MC absorbed dose calculations in post‐implant CT‐based phantoms. The virtual patient models used for 125I prostate implant MC absorbed dose calculations in this study are derived from the CT images of an external radiotherapy prostate patient without BT seeds and prostatic calcifications, thus averting the need to implement MAR and TAS.Methods: The geometry of the IsoSeed I25.S17plus source is validated by comparing the MC calculated results of the TG‐43 parameters for the line source approximation with the TG‐43U1S2 consensus data. Four MC absorbed dose calculations are performed in two virtual patient models using the egs_brachy MC code: (1) TG‐43‐based Dw,w‐TG43, (2) Dw,w‐MBDC that accounts for interseed scattering and attenuation (ISA), (3) Dm,m that examines ISA and tissue heterogeneity by scoring absorbed dose in tissue, and (4) Dw,m that unlike Dm,m scores absorbed dose in water. The MC absorbed doses (1) and (2) are simulated in a TG‐43 patient phantom derived by assigning the densities of every voxel to 1.00 g cm−3 (water), whereas MC absorbed doses (3) and (4) are scored in the TG‐186 patient phantom generated by mapping the mass density of each voxel to tissue according to a CT calibration curve. The MC absorbed doses calculated in this study are compared with VariSeed v8.0 calculated absorbed doses. To evaluate the dosimetric effect of MAR and TAS, the MC absorbed doses of this work (independent of MAR and TAS) are compared to the MC absorbed doses of different 125I source models from previous studies that were calculated with different MC codes using post‐implant CT‐based phantoms generated by implementing MAR and TAS on post‐implant CT images.Results: The very good agreement of TG‐43 parameters of this study and the published consensus data within 3% validates the geometry of the IsoSeed I25.S17plus source. For the clinical studies, the TG‐43‐based calculations show a D90 overestimation of more than 4% compared to the more realistic MC methods due to ISA and tissue composition. The results of this work generally show few discrepancies with the post‐implant CT‐based dosimetry studies with respect to the D90 absorbed dose metric parameter. These discrepancies are mainly Type B uncertainties due to the different 125I source models and MC codes.Conclusions: The implementation of MAR and TAS on post‐implant CT images have no dosimetric effect on the 125I prostate MC absorbed dose calculation in post‐implant CT‐based phantoms.Keywords
This publication has 29 references indexed in Scilit:
- Monte Carlo investigation of I‐125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFETMedical Physics, 2013
- Patient QA systems for rotational radiation therapy: A comparative experimental study with intentional errorsMedical Physics, 2013
- On the sensitivity of common gamma‐index evaluation methods to MLC misalignments in Rapidarc quality assuranceMedical Physics, 2013
- Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: Current status and recommendations for clinical implementationMedical Physics, 2012
- The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sourcesMedical Physics, 2011
- Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue compositionMedical Physics, 2010
- IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119Medical Physics, 2009
- Postimplant Dosimetry Using a Monte Carlo Dose Calculation Engine: A New Clinical StandardInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Tumour and target volumes in permanent prostate brachytherapy: A supplement to the ESTRO/EAU/EORTC recommendations on prostate brachytherapyRadiotherapy and Oncology, 2007
- Dosimetric effects of seed anisotropy and interseed attenuation for and prostate implantsMedical Physics, 2005