Improvement on Defect Detection Performance of PCB Inspection Based on ECT Technique With Multi-SV-GMR Sensor
Authors:
Open Access
- 21 May 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 43 (6) , 2394-2396
Abstract
This paper describes the improvement on the defect detection performance of printed circuit board (PCB) inspection based on the eddy-current testing (ECT) technique with the multispin-valve giant magnetoresistance (SV-GMR) sensor. To obtain the ECT signal in the same scanning line, SV-GMR sensors are mounted on the exciting coil in the same column parallel with the scanning direction. Harmonic analysis based on the Fourier transform is used to analyze the signal from the SV-GMR sensor in order to increase scanning speed. Then signal averaging is applied to the ECT signal in order to improve the signal-to-noise ratio. Experimental results are performed to verify the inspection performanceKeywords
This publication has 6 references indexed in Scilit:
- A GMR-Based Eddy Current System for NDE of Aircraft StructuresIEEE Transactions on Magnetics, 2006
- Application of eddy-current testing technique for high-density double-Layer printed circuit board inspectionIEEE Transactions on Magnetics, 2005
- A Novel Planar Mesh-Type Microelectromagnetic Sensor—Part I: Model FormulationIEEE Sensors Journal, 2004
- Application of ECT technique for inspection of bare PCBIEEE Transactions on Magnetics, 2003
- The effects of single-trial averaging upon the spatial extent of fMRI activationNeuroReport, 2001
- Wavelet-based processing of ECT images for inspection of printed circuit boardIEEE Transactions on Magnetics, 2001