Paediatric reference intervals for plasma anti-Müllerian hormone: comparison of data from the Roche Elecsys assay and the Beckman Coulter Access assay using the same cohort of samples
Open Access
- 19 March 2019
- journal article
- research article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 56 (5) , 536-547
Abstract
Background: Autoanalyser methods for the measurement of anti-Müllerian hormone have been introduced into clinical laboratories but few reports of paediatric reference intervals using these new assays have been published. Methods: After prior evaluation of the Roche Elecsys anti-Müllerian hormone assay against the Beckman Coulter modified second generation anti-Müllerian Hormone enzyme-linked immunosorbent assay using samples from adult females, a cohort of paediatric samples which had previously been assessed using the Beckman Coulter Access anti-Müllerian hormone assay was analysed using the Roche Elecsys anti-Müllerian hormone assay. Results: The Roche Elecsys anti-Müllerian hormone assay measured significantly lower than the Beckman Coulter modified second generation anti-Müllerian Hormone enzyme-linked immunosorbent assay. In the paediatric cohort measured with the Roche Elecsys assay, male levels are very high from birth to puberty after which they fall towards postpubertal female levels. Male results were similar to those previously obtained using the Beckman Coulter Access anti-Müllerian hormone assay on the same cohort. Roche Elecsys anti-Müllerian hormone in the females was very low in the neonatal and prepubertal years and the postpubertal trend, with a steady rise from 15 years, was smoother than previously modelled using the Beckman Coulter Access anti-Müllerian hormone assay. Conclusion: Anti-Müllerian hormone levels measured with the Roche Elecsys assay were significantly lower than the Beckman Coulter modified second generation enzyme-linked immunosorbent assay suggesting the need for new reference ranges. In the paediatric cohort, Roche Elecsys anti-Müllerian hormone levels between boys and girls showed good prepubertal delineation and small but statistically significant differences to previously measured levels using the Beckman Coulter Access anti-Müllerian hormone assay on the same sample cohort.Keywords
This publication has 32 references indexed in Scilit:
- Pre-mixing serum samples with assay buffer is a prerequisite for reproducible anti-Mullerian hormone measurement using the Beckman Coulter Gen II assayHuman Reproduction, 2014
- The Measurement of Anti-Müllerian Hormone: A Critical AppraisalThe Journal of Clinical Endocrinology & Metabolism, 2014
- First fully automated immunoassay for anti-Müllerian hormoneClinical Chemistry and Laboratory Medicine (CCLM), 2014
- Anti-Müllerian Hormone: A Valuable Addition to the Toolbox of the Pediatric EndocrinologistInternational Journal of Endocrinology, 2013
- Serum AMH in Physiology and Pathology of Male GonadsInternational Journal of Endocrinology, 2013
- Anti-Müllerian Hormone and Its Clinical Use in Pediatrics with Special Emphasis on Disorders of Sex DevelopmentInternational Journal of Endocrinology, 2013
- Anti-Mullerian hormone: poor assay reproducibility in a large cohort of subjects suggests sample instabilityHuman Reproduction, 2012
- A Validated Model of Serum Anti-Müllerian Hormone from Conception to MenopausePLOS ONE, 2011
- Serum Levels of Anti-Müllerian Hormone as a Marker of Ovarian Function in 926 Healthy Females from Birth to Adulthood and in 172 Turner Syndrome PatientsThe Journal of Clinical Endocrinology & Metabolism, 2010
- Anti-Müllerian Hormone and Sertoli Cell Function in Paediatric Male HypogonadismHormone Research in Paediatrics, 2010