Point‐of‐care detection of Japanese encephalitis virus biomarker in clinical samples using a portable smartphone‐enabled electrochemical “Sensit” device
Open Access
- 13 April 2023
- journal article
- research article
- Published by Wiley in Bioengineering & Translational Medicine
- Vol. 8 (3) , e10506
Abstract
Japanese encephalitis (JE), a neglected tropical zoonotic disease prevalent in south‐east Asian and western pacific countries, caused by the flavivirus JE virus (JEV), has a dearth of electrochemical point‐of‐care (PoC) diagnostic tools available to manage endemic breakouts. To overcome this, we have developed a screen‐printed carbon electrode (SPCE) immunosensor for rapid PoC detection of JEV nonstructural 1 (NS1) antigen (Ag), found circulating in serum of infected individuals using a smartphone based portable “Sensit” device. The modification of SPCE surface with JEV NS1 antibody (Ab) was confirmed via observation of globular protein structures via scanning electron microscopy (SEM), increase in electrode surface hydrophilicity via contact angle measurement and decrease in current via differential pulse voltammetry (DPV). The fabrication and testing parameters were optimized based on highest current output obtained using DPV. The SPCE was tested for detection limit of target JEV NS1 Ag ranging from 1 fM to 1 μM, which was determined as 0.45 fM in spiked serum. The disposable immunosensor was also found to be highly specific in detecting JEV NS1 Ag over other flaviviral NS1 Ag. Finally, the modified SPCE was clinically validated by testing 62 clinical JEV samples using both a portable miniaturized electrochemical “Sensit” device coupled with a smartphone and a laboratory‐based potentiostat. The results were corroborated with gold‐standard RT‐PCR and showed 96.77% accuracy, 96.15% sensitivity, and 97.22% specificity. Hence, this technique may further be developed into a one‐step rapid diagnostic tool for JEV, especially in rural areas.Keywords
Funding Information
- Department of Biotechnology, Ministry of Science and Technology, India (BT/AAQ/01/NIAB‐Flagship/2019)
This publication has 64 references indexed in Scilit:
- Comprehensive Mapping Antigenic Epitopes of NS1 Protein of Japanese Encephalitis Virus with Monoclonal AntibodiesPLOS ONE, 2013
- Japanese encephalitis: a review of the Indian perspectiveThe Brazilian Journal of Infectious Diseases, 2012
- Facile fabrication of magnetic gold electrode for magnetic beads-based electrochemical immunoassay: Application to the diagnosis of Japanese encephalitis virusBiosensors and Bioelectronics, 2011
- Global trends in emerging infectious diseasesNature, 2008
- A label-free amperometric immunosenor based on multi-layer assembly of polymerized o-phenylenediamine and gold nanoparticles for determination of Japanese B encephalitis vaccineAnalytica Chimica Acta, 2005
- The Correlation between Serum Selenium and Blood Selenium in CattleJournal of Veterinary Diagnostic Investigation, 1992
- The effect of temperature on the binding kinetics and equilibrium constants of monoclonal antibodies to cell surface antigensMolecular Immunology, 1990
- Maturation of Japanese encephalitis virus glycoproteins produced by infected mammalian and mosquito cellsVirology, 1989
- Japanese Encephalitis — A Plague of the OrientNew England Journal of Medicine, 1988
- Evaluation of the optimal incubation temperature for detecting certain IgG antibodies with potential clinical significanceTransfusion, 1988