Abstract
STUDY QUESTION: How well does multi-analyte steroid mass spectrometry ( MS) profiling classify women with and without polycystic ovary syndrome PCOS)? SUMMARY ANSWER: Our liquid chromatography MS (LC-MS) steroid profiling only minimally improves discrimination of women with and without PCOS compared with a direct testosterone immunoassay (T_IA) and the free androgen index (FAI). WHAT IS KNOWN ALREADY: Blood testosterone measured by direct (non-extraction) immunoassay overlaps between women with and without PCOS. Multi-analyte MS provides greater specificity and accuracy for steroid measurement so might improve the classification. STUDY DESIGN, SIZE, DURATION: An observational, cross-sectional study of women with PCOS (n = 152) defined by Rotterdam criteria and matched non-PCOS (n = 45) control women was conducted. PARTICIPANTS/MATERIALS, SETTING, METHODS: Serum steroid profiles of testosterone (T), dihydrotestosterone (DHT), dehydroepiandrosterone (DHEA), androstenedione (A(4)), estradiol (E-2), estrone (E-1), 17 hydroxy progesterone (17OHP(4)), progesterone (P-4) and cortisol were measured by LC-MS; T_IA and sex hormone binding globulin were measured by immunoassay; and FAI, calculated free testosterone (cFT) and total androgen index (TAI) were calculated. Classification was based on logistic regression with corresponding univariate and multivariate C-statistics. MAIN RESULTS AND THE ROLE OF CHANCE: Serum testosterone by immunoassay demonstrated levels more than 100% higher than that measured by LC-MS. Compared with the controls, women with PCOS had higher serum T, DHEA, A(4), TAI, T_IA, cFT, FAI and E-2 but not serum DHT, E-1, P-4, 17OHP(4) or cortisol. Univariate C-statistics were highest for FAI (0.89) and T_IA (0.82) compared with other androgens (T [0.72], DHT [0.40]), pro-androgens (A4 [0.74], DHEA[0.71]) or derivatives (cFT [0.75], TAI [0.60]). For all multivariate models, the overall correct predictions (81-86%) featured high sensitivity (92-96%) but low specificity (28-43%). and substituting LC-MS steroid measurements for T_IA and FAI produced only minimal improvements in classification. LIMITATIONS REASONS FOR CAUTION: The study cohort is limited in size and only unconjugated steroids were measured. WIDER IMPLICATIONS OF THE FINDINGS: Multi-analyte steroid profiling of unconjugated circulating steroids provides only limited improvement on direct T_IA in classifying women with and without PCOS.Keywords
This publication has 27 references indexed in Scilit:
- Age-specific population centiles for androgen status in menEuropean Journal of Endocrinology, 2015
- Scientific Statement on the Diagnostic Criteria, Epidemiology, Pathophysiology, and Molecular Genetics of Polycystic Ovary SyndromeEndocrine Reviews, 2015
- Reproductive Hormones and Longitudinal Change in Bone Mineral Density and Incident Fracture Risk in Older Men: The Concord Health and Aging in Men ProjectJournal of Bone and Mineral Research, 2015
- The polycystic ovary syndrome: a position statement from the European Society of EndocrinologyEuropean Journal of Endocrinology, 2014
- Simultaneous Measurement of Thirteen Steroid Hormones in Women with Polycystic Ovary Syndrome and Control Women Using Liquid Chromatography-Tandem Mass SpectrometryPLOS ONE, 2014
- Requirement for Mass Spectrometry Sex Steroid Assays in the Journal of Clinical Endocrinology and MetabolismThe Journal of Clinical Endocrinology & Metabolism, 2013
- Assessment of androgen concentration in women: liquid chromatography–tandem mass spectrometry and extraction RIA show comparable resultsEuropean Journal of Endocrinology, 2011
- Defining hyperandrogenism in polycystic ovary syndrome: measurement of testosterone and androstenedione by liquid chromatography–tandem mass spectrometry and analysis by receiver operator characteristic plotsEuropean Journal of Endocrinology, 2010
- Development and validation of a sensitive liquid chromatography–tandem mass spectrometry assay to simultaneously measure androgens and estrogens in serum without derivatizationClinica Chimica Acta, 2009
- Ultrasound assessment of the polycystic ovary: international consensus definitionsHuman Reproduction Update, 2003