Automatic stent reconstruction in optical coherence tomography based on a deep convolutional model
- 29 May 2020
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (6) , 3374-3394
Abstract
Intravascular optical coherence tomography (IVOCT) can accurately assess stent apposition and expansion, thus enabling the optimisation of a stenting procedure to minimize the risk of device failure. This paper presents a deep convolutional based model for automatic detection and segmentation of stent struts. The input of pseudo-3D images aggregated the information from adjacent frames to refine the probability of strut detection. In addition, multi-scale shortcut connections were implemented to minimize the loss of spatial resolution and refine the segmentation of strut contours. After training, the model was independently tested in 21,363 cross-sectional images from 170 IVOCT image pullbacks. The proposed model obtained excellent segmentation (0.907 Dice and 0.838 Jaccard) and detection metrics (0.943 precision, 0.940 recall and 0.936 F1-score), significantly better than conventional features-based algorithms. This performance was robust and homogenous among IVOCT pullbacks with different sources of acquisition (clinical centres, imaging operators, type of stent, time of acquisition and challenging scenarios). In addition, excellent agreement between the model and a commercialized software was observed in the quantification of clinically relevant parameters. In conclusion, the deep-convolutional model can accurately detect stent struts in IVOCT images, thus enabling the fully-automatic quantification of stent parameters in an extremely short time. It might facilitate the application of quantitative IVOCT analysis in real-world clinical scenarios.Keywords
Funding Information
- National Natural Science Foundation of China (Grant No. 81871460)
- Program of Shanghai Technology Research Leader
- Shanghai Jiao Tong University (Grant No. ZH2018ZDB10)
This publication has 35 references indexed in Scilit:
- Automatic stent detection in intravascular OCT images using bagged decision treesBiomedical Optics Express, 2012
- Automatic stent strut detection in intravascular optical coherence tomographic pullback runsThe International Journal of Cardiovascular Imaging, 2012
- Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomographyThe International Journal of Cardiovascular Imaging, 2012
- Optical coherence tomography: from research to practiceEuropean Heart Journal - Cardiovascular Imaging, 2012
- Vascular Tissue Reaction to Acute Malapposition in Human Coronary ArteriesCirculation: Cardiovascular Interventions, 2012
- Automatic vessel lumen segmentation and stent strut detection in intravascular optical coherence tomographyMedical Physics, 2011
- Comprehensive Intravascular Ultrasound Assessment of Stent Area and Its Impact on Restenosis and Adverse Cardiac Events in 403 Patients With Unprotected Left Main DiseaseCirculation: Cardiovascular Interventions, 2011
- Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverageThe International Journal of Cardiovascular Imaging, 2011
- Mechanisms of In-Stent Restenosis After Drug-Eluting Stent ImplantationCirculation: Cardiovascular Interventions, 2011
- Global and regional causes of deathBritish Medical Bulletin, 2009