Modification of fibrinogen with poly(ethylene glycol) and its effects on fibrin clot characteristics
Authors:
- 30 May 2001
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 56 (4) , 529-535
Abstract
The suitability of existing topical fibrin glue preparations for tissue sealing or local drug delivery applications is greatly limited by their poor mechanical properties and the limited capacity of fibrinogen (Fgn) to actively bind growth factors or other therapeutic agents. Poly(ethylene glycol) (PEG) offers potential solutions to these problems by providing a mechanism for increasing the number of crosslinks between adjacent fibrin monomer molecules or for covalently crosslinking Fgn to therapeutic agents. The feasibility of this approach requires the full biological activity, or clottability, of PE glycolated Fgn. This study characterizes the clot characteristics of Fgn modified to varying degrees with monofunctional succinimidyl propionate PEG (5000 Da). The data indicate that, although thrombin clotting times are significantly altered, Fgn maintains 90% of its capacity to clot upon the addition of up to 5 PEG/Fgn. Further derivatization significantly decreases the Fgn clottability. The addition of up to 5 PEG/Fgn has little, if any, effect on the kinetics of degradation by plasmin. The results suggest that limited modification of Fgn with lysine-reactive PEG allows therapeutic enhancement of fibrin glues. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 56: 529–535, 2001Keywords
This publication has 30 references indexed in Scilit:
- Conformational Changes in Fragments D and Double-D from Human Fibrin(ogen) upon Binding the Peptide Ligand Gly-His-Arg-Pro-Amide,Biochemistry, 1999
- Binding of Basic Fibroblast Growth Factor to Fibrinogen and FibrinJournal of Biological Chemistry, 1998
- Fibrin Sealant: Scientific Rationale, Production Methods, Properties, and Current Clinical UseVox Sanguinis, 1997
- Biomedical and biotechnological applications of PEG- and PM-modified proteinsTrends in Biotechnology, 1995
- Pegylated peptides IIInternational Journal of Peptide and Protein Research, 1994
- Fibrin Sealant Adhesive Systems: A Review of Their Chemistry, Material Properties and Clinical ApplicationsJournal of Biomaterials Applications, 1993
- Polymer–micelle interactions: physical organic aspectsChemical Society Reviews, 1993
- Autologous fibrin tissue adhesive biodegration and systemic effectsThe Laryngoscope, 1987
- Effects of Polyethylene Glycol Substitution on Enzyme ActivityJournal of Bioactive and Compatible Polymers, 1987
- A Study of the Conditions and Accuracy of the Thrombin Time Assay of Plasma FibrinogenActa Haematologica, 1982