Noninvasive Assessment of Myocardial Inflammation by Cardiovascular Magnetic Resonance in a Rat Model of Experimental Autoimmune Myocarditis
Authors:
- Hyo Eun ParkHPHyo Eun Park
- Jongeun KangJKJongeun Kang
- Hyunseung LeeHLHyunseung Lee
- Chaejoon CheongCCChaejoon Cheong
- Yong Taik LimYLYong Taik Lim
- Sang-Hyun IhmSISang-Hyun Ihm
- Ki-Bae SeungKSKi-Bae Seung
- Farouc A. JafferFJFarouc A. Jaffer
- Jagat NarulaJNJagat Narula
- Kiyuk ChangKCKiyuk Chang
- Kwan Soo HongKHKwan Soo Hong
- 29 May 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 125 (21) , 2603-2612
Abstract
Background—: Limited availability of noninvasive and biologically precise diagnostic tools poses a challenge for the evaluation and management of patients with myocarditis. Methods and Results—: The feasibility of cardiovascular magnetic resonance (CMR) imaging with magneto-fluorescent nanoparticles (MNPs) for detection of myocarditis and its effectiveness in discriminating inflammation grades were assessed in experimental autoimmune myocarditis (EAM) (n=65) and control (n=10) rats. After undergoing CMR, rats were administered with MNPs, followed by a second CMR 24 hours later. Head-to-head comparison of MNP-CMR with T 2 -weighted, early and late gadolinium enhancement CMR was performed in additional EAM (n=10) and control (n=5) rats. Contrast-to-noise ratios were measured and compared between groups. Flow cytometry and microscopy demonstrated that infiltrating inflammatory cells engulfed MNPs, resulting in altered myocardial T 2 * effect. Changes in contrast-to-noise ratio between pre- and post-MNP CMR were significantly greater in EAM rats (1.08±0.10 versus 0.48±0.20; P P P <0.001) and detectability of focal myocardial inflammation. Notably, MNP-CMR successfully tracked the evolution of myocardial inflammation in the same EAM rats. Conclusions—: Magneto-fluorescent nanoparticle CMR permitted effective visualization of myocardial inflammatory cellular infiltrates and distinction of the extent of inflammation compared with conventional CMR in a preclinical model of EAM. Magneto-fluorescent nanoparticle CMR performs best in EAM rats with at least moderate inflammatory response.Keywords
This publication has 29 references indexed in Scilit:
- Noninvasive imaging of pancreatic islet inflammation in type 1A diabetes patientsJournal of Clinical Investigation, 2011
- Cardiovascular Magnetic Resonance in Myocarditis: A JACC White PaperJACC, 2009
- Suppression of Inflammation in Rat Autoimmune Myocarditis by S100A8/A9 Through Modulation of the Proinflammatory Cytokine NetworkEuropean Journal of Heart Failure, 2009
- Noninvasive Detection of Macrophage-Rich Atherosclerotic Plaque in Hyperlipidemic Rabbits Using “Positive Contrast” Magnetic Resonance ImagingJACC, 2008
- Acute viral myocarditisEuropean Heart Journal, 2008
- Correlation of Carotid Atheromatous Plaque Inflammation Using USPIO-Enhanced MR Imaging With Degree of Luminal StenosisStroke, 2008
- Nanoparticle PET-CT Imaging of Macrophages in Inflammatory AtherosclerosisCirculation, 2008
- Magnetic resonance imaging detection of rat renal transplant rejection by monitoring macrophage infiltrationKidney International, 2000
- Sudden unexpected death in persons <40 years of ageThe American Journal of Cardiology, 1991
- Usefulness of magnetic resonance imaging for diagnosis of acute myocarditis in infants and children, and comparison with endomyocardial biopsyThe American Journal of Cardiology, 1991