Wear and fracture of curettes due to sharpening and scaling processes
- 26 December 2021
- journal article
- research article
- Published by Wiley in International Journal of Dental Hygiene
- Vol. 20 (3) , 564-570
Abstract
Objectives: To examine the wear occurring in a group of new Gracey curettes due to the sharpening and scaling processes and record the number of service cycles before breakage.Methods: This study included 592 working ends of Gracey curettes that were subjected to cycles of sharpening and scaling. Three‐dimensional measurements of the blades and the status of the working ends were recorded before and after each process.Results: With an increase in the number of usage cycles, the three‐dimensional measurements of the blades decreased. During this study, 184 working ends were broken, of which 38.59% were of #11/12 Gracey curettes, and only 8.15% were of #7/8 Gracey curettes. The average number of cycles required for the fracture of Gracey curettes was 14.34. Cox regression analyses showed that the factors influencing the survival cycles were the tip width before usage and the type of Gracey curette. Moreover, the sharpening process was responsible for approximately half of the total instrument wear. Among the four types of Gracey curettes, the #11/12 Gracey curettes showed the greatest amount of sharpening wear, accounting for >50% of the total wear.Conclusions: The service life of Gracey curettes varies according to their types; the #11/12 Gracey curettes are more susceptible to breakage, while #7/8 Gracey curettes tend to have a long service life. Furthermore, the sharpening process was responsible for a considerable amount of curette wear.Keywords
This publication has 9 references indexed in Scilit:
- In Vitro Evaluation of the Effect of Chemical and Thermal Stress of the Mechanical Properties of Periodontal Curettes under Simulated Conditions of Sharpening Wear2017
- Periodontitis: a polymicrobial disruption of host homeostasisNature Reviews Microbiology, 2010
- Aspiration and ingestion in dental practiceThe Journal of the American Dental Association, 2004
- Scanning Electron Microscope Evaluation of Two Methods of Resharpening Periodontal Curets: A Comparative StudyJournal of Periodontology, 2003
- Subgingival Microbiota of Brazilian Subjects With Untreated Chronic PeriodontitisJournal of Periodontology, 2002
- Scanning Electron Microscope Evaluation of Wear of Stainless Steel and High Carbon Steel CurettesJournal of Periodontology, 1989
- Scanning Electron Microscope Evaluation of Wear of Dental Curettes during Standardized Root PlaningJournal of Periodontology, 1985
- The Effects of Two Sharpening Methods on the Strength of a Periodontal Scaling InstrumentJournal of Periodontology, 1984
- Effects of Sterilization on Periodontal InstrumentsJournal of Periodontology, 1982