Accelerated analysis of three-dimensional blood flow of the thoracic aorta in stroke patients
- 15 August 2014
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 30 (8) , 1571-1577
Abstract
To test if new software accelerates analysis of in vivo acquired 4D flow MRI data. Respiration-gated and ECG-synchronized 4D flow MRI of the aorta was performed in 20 stroke patients using a routine 3-Tesla MRI system (TIMTRIO, Siemens, Germany). 3D blood flow data was processed by one experienced observer using new (A = MEVISFlow) and widely-used software (B = EnSight + Velomap-/FlowTool). Evaluation included: inter-/intra-observer variability of software A and inter-software comparison regarding (1) blood flow quantification (total-/peak flow) and (2) flow visualisation, plus (3) measurement of the time required for visualization and quantification of data (software A&B). (1) Inter-/intra-observer agreement of software A (mean difference ≤5.2 and ≤0.9 %, respectively) and inter-software agreement (mean difference ≤ 2.2 %) was high with high correlation of peak and total blood flow (r ≥ 0.74; p < 0.001 and r ≥ 0.91; p < 0.001). (2) Comparison of blood flow visualization showed substantial agreement (κ ≥ 0.68). (3) Data-analysis was three times faster when using software A [18:10 (±1:29) vs. 58:30 (±5:28) min; p < 0.0001]. Acceleration of blood flow quantification and visualisation using new software strongly facilitates future applications of 4D flow MRI and thus enables its usage in larger patient cohorts in clinical research and routine.Keywords
This publication has 29 references indexed in Scilit:
- A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imagingJournal of Vascular Surgery, 2012
- 4-D blood flow in the human right ventricleAmerican Journal of Physiology-Heart and Circulatory Physiology, 2011
- Four-dimensional phase contrast magnetic resonance angiography: Potential clinical applicationsEuropean Journal of Radiology, 2011
- Reproducibility of flow and wall shear stress analysis using flow‐sensitive four‐dimensional MRIJournal of Magnetic Resonance Imaging, 2011
- In vivo three‐dimensional MR wall shear stress estimation in ascending aortic dilatationJournal of Magnetic Resonance Imaging, 2011
- In Vivo Wall Shear Stress Distribution in the Carotid ArteryCirculation: Cardiovascular Imaging, 2010
- Complex Plaques in the Proximal Descending AortaStroke, 2010
- Complete Intracranial Arterial and Venous Blood Flow Evaluation with 4D Flow MR ImagingAmerican Journal of Neuroradiology, 2008
- Semiautomated method for noise reduction and background phase error correction in MR phase velocity dataJournal of Magnetic Resonance Imaging, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986