Synchronization and Calibration of the 24-Modules J-PET Prototype With 300-mm Axial Field of View
- 1 January 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Abstract
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 ± 9 ps. This value can be translated to the position reconstruction accuracy σ(Δ) = 18 mm which is fairly position-independent Keywords: positron emission tomography, plastic scintillators, J-PET.Keywords
All Related Versions
Funding Information
- The Polish National Center for Research and Development (INNOTECH-K1/IN1/64/159174/NCBR/12)
- Foundation for Polish Science through the MPD and TEAM Programs (POIR.04.04.00-00-4204/17)
- Narodowe Centrum Nauki (2016/21/B/ST2/01222)
- Narodowe Centrum Nauki (2017/25/N/NZ1/00861)
- Ministry for Science and Higher Education (6673/IA/SP/2016)
- Ministry for Science and Higher Education (7150/E338/SPUB/2017/1)
- Ministry for Science and Higher Education (7150/E-338/M/2017)
- Austrian Science Fund (FWF-P26783)
This publication has 39 references indexed in Scilit:
- Compressive sensing of signals generated in plastic scintillators in a novel J-PET instrumentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Analysis Framework for the J-PET ScannerActa Physica Polonica A, 2015
- Dual-Phase Tapped-Delay-Line Time-to-Digital Converter With On-the-Fly Calibration Implemented in 40 nm FPGAIEEE Transactions on Biomedical Circuits and Systems, 2015
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signalsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission TomographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic raysBio-Algorithms and Med-Systems, 2014
- A novel method based solely on field programmable gate array (FPGA) units enabling measurement of time and charge of analog signals in positron emission tomography (PET)Bio-Algorithms and Med-Systems, 2014
- A compact system for high precision time measurements ( < 14 ps RMS) and integrated data acquisition for a large number of channelsJournal of Instrumentation, 2011
- A multi-threshold sampling method for TOF-PET signal processingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Benefit of Time-of-Flight in PET: Experimental and Clinical ResultsJournal of Nuclear Medicine, 2008