Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients
Open Access
- 24 July 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (33) , 12391-12397
Abstract
For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (Er < 4%) and good precision (RSD ≤ 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited.Keywords
Funding Information
- Comunidad de Madrid (P2018/NMT-4349)
- Ministerio de Ciencia e Innovaci?n (PID2020-118154GB-I00)
- Ministerio de Econom?a y Competitividad (CTQ2017-86441-C2-1-R)
- Instituto de Salud Carlos III (2021SGR00925, RD21/0006/0024)
This publication has 35 references indexed in Scilit:
- Iron overload, measured as serum ferritin, increases brain damage induced by focal ischemia and early reperfusionNeurochemistry International, 2012
- Diagnostic value of transferrinClinica Chimica Acta, 2012
- Reference measurement procedures for the iron saturation in human transferrin based on IDMS and Raman scatteringMetallomics, 2012
- Which is the best way for estimating transferrin saturation?Renal Failure, 2010
- Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based MicrofluidicsAnalytical Chemistry, 2009
- Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable BioassaysAngewandte Chemie International Edition, 2007
- Transferrin saturation with intravenous irons: An in vitro studyKidney International, 2004
- Non–Transferrin-Bound Iron in the Serum of Hemodialysis Patients Who Receive Ferric SaccharateJournal of the American Society of Nephrology, 2004
- Iron intake increases infarct volume after permanent middle cerebral artery occlusion in ratsBrain Research, 2002
- Ferrozine---a new spectrophotometric reagent for ironAnalytical Chemistry, 1970