Flat-detector computed tomography (FD-CT)
Top Cited Papers
- 23 June 2007
- journal article
- review article
- Published by Springer Nature in European Radiology
- Vol. 17 (11) , 2767-2779
Abstract
Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room.Keywords
This publication has 54 references indexed in Scilit:
- Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CTPhysics in Medicine & Biology, 2006
- Large area mercuric iodide and lead iodide X-ray detectors for medical and non-destructive industrial imagingJournal of Crystal Growth, 2005
- Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesisNature Medicine, 2004
- Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiographyDentomaxillofacial Radiology, 2004
- A performance comparison of flat‐panel imager‐based MV and kV cone‐beam CTMedical Physics, 2002
- Effect of scattered radiation on image noise in cone beam CTMedical Physics, 2001
- Efficient correction for CT image artifacts caused by objects extending outside the scan field of viewMedical Physics, 2000
- Flat panel detector-based cone-beam volume CT angiography imaging: system evaluationIEEE Transactions on Medical Imaging, 2000
- Geometrical calibration of x-ray imaging chains for three-dimensional reconstructionComputerized Medical Imaging and Graphics, 1993
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984