Monitoring of organic pollutants in marine environment by semipermeable membrane devices and mussels: accumulation and biochemical responses
- 28 June 2017
- journal article
- research article
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (23) , 19114-19125
Abstract
This study involves the monitoring of organic pollutants using transplanted mussels (Mytilus galloprovincialis) as bioindicator organisms and semipermeable membrane devices (SPMDs) as passive samplers. Mussels and SPMDs were deployed to marinas, shipyards and shipbreaking yards on the coastal area of Turkey and retrieved after 60 days. Polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB) and organochlorine pesticide (OCP) compounds were analysed with high-resolution GC-MS. Total PAH concentrations in SPMDs and mussels ranged from 200 to 4740 ng g sampler−1 and from 7.0 to 1130 ng g−1 in wet weight (ww). PCB and OCP concentrations in SPMDs changed between 0.04–200 and 4.0–26 ng g sampler−1, respectively. The highest PCB (190 ng g−1 ww) and OCP (200 ng g−1 ww) concentrations in mussels were measured at shipyard stations. A strong correlation was observed between the PAH and PCB concentrations in SPMDs and mussels. Enzyme assays (acetylcholinesterase, ethoxyresorufin-O-deethylase, glutathione S-transferase, glutathion reductase and carboxylesterase activities) were performed as biomarkers to reveal the effects of pollution on the mussels. There was no clear relationship found between the enzyme levels and the pollutant concentrations in mussels. Integrated biomarker responses were calculated to interpret the overall effect of pollutants.Keywords
Funding Information
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu (110Y194)
- Bundesministerium für Forschung, Technologie und Raumfahrt (PT-DLR 01DL12016)
This publication has 90 references indexed in Scilit:
- Distribution and Bioconcentration of Polycyclic Aromatic Hydrocarbons in Surface Water and FishesThe Scientific World Journal, 2012
- Calibration of Silicone Rubber Passive Samplers: Experimental and Modeled Relations between Sampling Rate and Compound PropertiesEnvironmental Science & Technology, 2009
- Modelling and field application of the Chemcatcher passive sampler calibration data for the monitoring of hydrophobic organic pollutants in waterEnvironmental Pollution, 2007
- Polyethylene Devices: Passive Samplers for Measuring Dissolved Hydrophobic Organic Compounds in Aquatic EnvironmentsEnvironmental Science & Technology, 2007
- Metabolic activation of polycyclic and heterocyclic aromatic hydrocarbons and DNA damage: A reviewToxicology and Applied Pharmacology, 2005
- Organophosphate Toxicology: Safety Aspects of Nonacetylcholinesterase Secondary TargetsChemical Research in Toxicology, 2004
- Use of semipermeable membrane devices (SPMDs)Environmental Science and Pollution Research, 2001
- Induction of cytochrome P450 as a biomarker for environmental contamination in aquatic ecosystemsCritical Reviews in Environmental Science and Technology, 1995
- A thermodynamic-based evaluation of organic chemical accumulation in aquatic organismsEnvironmental Science & Technology, 1988
- A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye bindingAnalytical Biochemistry, 1976