Abstract
In this paper, Oscillation-based Test Methodology (OTM) is evaluated in the context of MEMS testing. Both qualitative and quantitative evaluations of fault coverage are discussed and the impact of test on production yield is addressed. This article also introduces the Lorentz force as a low-cost stimulus for electro-mechanical structures.Keywords
This publication has 6 references indexed in Scilit:
- Effective oscillation-based test for application to a DTMF filter bank2003
- Parametric and catastrophic fault coverage of analog circuits in oscillation-test methodology2002
- Electrically induced stimuli for MEMS self-test2002
- High-level fault modeling in surface-micromachined MEMS2000
- A fault simulation methodology for MEMS2000
- Failure mechanisms and fault classes for CMOS-compatible microelectromechanical systems1998