Background. Estimation of glomerular filtration rate (GFR) from serum creatinine (S cr ) or cystatin C (Cys C) exhibit variable performances. Methods. We compared the performances of 14 S cr and 9 Cys C estimated GFR equations using inulin clearance (Cl in ) as the reference test in 103 stable renal transplant populations. Bias, precision, receiving operation characteristics (ROC), accuracy within 30% ranges from the reference method and agreements of each test were compared. Results. Mean Cl in was 46.4 ± 20.9 ml/min/1.73 m 2 . S cr and Cys C levels correlated well with each other ( r = 0.83, P < 0.0001) and with Cl in ( r = −0.57 and −0.53, P < 0.001, respectively). ROC analysis demonstrated no superiority of Cys C over S cr . Gats equation achieved the highest accuracy of 70% in patients with GFR ≥60 ml/min/1.73 m 2 . In patients with GFR ≥60 ml/min/1.73 m 2 , the Nankivell equation demonstrated the highest accuracy of 73.91%. Cys C-based equations were not depicted to be thoroughly accurate. Bias, precision and agreement were otherwise similar in all GFR tests. Conclusion. S cr -based equations did not appear to be inferior to Cys C-based equations as a means to estimate GFR in renal transplant patients.