3D Freehand Ultrasound Imaging of Optic Nerve Sheath
Open Access
- 26 November 2025
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (8) , 516-526
Abstract
Objectives: The optic nerve sheath expands with elevated intracranial pressure, and its diameter is a sensitive proxy measure. While 2D transorbital ultrasound is well-established for detecting elevated intracranial pressure (>20 mm Hg), it shows limited sensitivity to modest or gradual changes, potentially due to geometric assumptions and imaging misalignment. This study introduces freehand 3D ultrasound imaging of the optic nerve sheath to reduce measurement ambiguity and enhance the fidelity of optic nerve sheath assessment as a noninvasive marker of intracranial pressure. Materials and Methods: Twelve healthy participants (28.7 ± 8.2 y; 6 females) underwent freehand 3D optic nerve sheath imaging during 24 hours of normobaric hypoxia in an environmental chamber (FiO 2 = 13.1%). Scans were acquired in a head-raised (30 degrees) position at baseline, 6, 12, and 24 hours. Cardiorespiratory parameters, cerebral blood flow, and end-tidal gases were recorded. In 6 participants, postural effects were also assessed at baseline. Nutrition and hydration were standardized to 75% of daily requirements. Results: The optic nerve sheath’s curved, noncircular shape makes the 2D diameter measurement of the sheath a geometric mismatch and an inadequate descriptor. Probe misalignments of 1.2 mm or 15 degrees led to 2D diameter errors (9%/18.7%) exceeding observer variability (2.6%/3.4%). Freehand 3D imaging was reproducible and yielded more informative metrics, including sheath area and thickness. Internal sheath thickness was more responsive to posture and hypoxia than internal 2D diameter (+31.5%, P = 0.01 vs +2.4%, P = 0.9; +8.2%, P = 0.04 vs +1.8%, P = 0.9). A time effect was observed for internal sheath thickness ( P = 0.04), and both area and thickness correlated with internal carotid artery velocity (area: r = 0.9, P = 0.05; thickness: r = 0.8, P = 0.07), consistent with physiological expectations. Conclusion: By eliminating geometric assumptions and misalignment, freehand 3D ultrasound improves the fidelity and sensitivity of optic nerve sheath measurements at the bedside.Keywords
This publication has 37 references indexed in Scilit:
- Factors associated with optic nerve sheath diameter during exposure to hypobaric hypoxiaNeurology, 2014
- Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imagingBMC Neurology, 2013
- Postural effects on intracranial pressure: modeling and clinical evaluationJournal of Applied Physiology, 2013
- Volumetric Assessment of Optic Nerve Sheath and Hypophysis in Idiopathic Intracranial HypertensionAmerican Journal of Neuroradiology, 2013
- Optic Nerve Sheath Diameter Is Not Related to High Altitude Headache: A Randomized Controlled TrialHigh Altitude Medicine & Biology, 2012
- Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysisIntensive Care Medicine, 2011
- Optic nerve sheath diameter correlates with the presence and severity of acute mountain sickness: evidence for increased intracranial pressureJournal of Applied Physiology, 2009
- 3D ultrasound coronal C-scan imaging for optic nerve sheath meningiomaBritish Journal of Ophthalmology, 2005
- A 3-dimensional ultrasound C-scan imaging technique for optic nerve measurements*1Ophthalmology, 2004
- C-scan ultrasonography in orbital diagnosis.British Journal of Ophthalmology, 1977