Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device
Authors:
- 1 August 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 32 (8) , 1331-1335
Abstract
To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. Forty-two phakic and 42 pseudophakic patients with normal axial lengths (mean 22.91 mm +/- 1.21 [SD]) were enrolled in the study. The ACD was measured 3 times with Scheimpflug-based Pentacam (Oculus) and then 3 times with a standard A-scan US device (AL-2000, Tomey). The data were then analyzed. In the phakic group, the mean ACD was 2.87 +/- 0.4 mm with the Pentacam and 2.89 +/- 0.49 mm with ultrasound A-scan (US) (P = .84). In the pseudophakic group, the mean ACD was 3.41 +/- 0.28 mm and 3.97 +/- 0.45 mm, respectively (P < .001). The correlation between measurements was significant in both the phakic and pseudophakic groups (r = .547/P < .001 and r = .404/P = .01, respectively). In phakic eyes, ACD measured with the Pentacam and with US was the same. However, in pseudophakic eyes, the difference was significantly lower when the ACD was measured with the Pentacam. Therefore, in pseudophakic patients, further evaluation of ACD data with the Scheimpflug-based system is necessary.Keywords
This publication has 22 references indexed in Scilit:
- Intraocular lens movement caused by ciliary muscle contractionJournal of Cataract & Refractive Surgery, 2003
- Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lensJournal of Cataract & Refractive Surgery, 2003
- A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in asian eyesOphthalmology, 2003
- Complications of foldable intraocular lenses requiring explantation or secondary intervention—1998 surveyJournal of Cataract & Refractive Surgery, 2000
- Intraocular lens movement and accommodation in eyes of young patientsJournal of Cataract & Refractive Surgery, 2000
- Anterior Chamber Depth Measurement as a Screening Tool for Primary Angle-closure Glaucoma in an East Asian PopulationArchives of Ophthalmology (1950), 2000
- Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1997
- Intraocular lens power calculation with an improved anterior chamber depth prediction algorithmJournal of Cataract & Refractive Surgery, 1995
- Anterior Chamber Dimensions in Patients With Narrow Angles and Angle-closure GlaucomaArchives of Ophthalmology (1950), 1984
- Anterior Chamber Depth Measurement Using the Slit-Lamp MicroscopeAmerican Journal of Ophthalmology, 1979