Orthodontic Alloy Wires and Their Hypoallergenic Alternatives: Metal Ions Release in pH 6.6 and pH 5.5 Artificial Saliva
Open Access
Abstract
Legislative framework addresses the issues of alloy corrosion, demanding the restricted use of probable carcinogenic, mutagenic, and toxic-for-human-reproduction (CMG) metals like nickel, cobalt, and chromium and demanding the development of new biomaterials. The aim of this research was to evaluate and compare the ion release of standard dental alloys and their hypoallergenic equivalents. Six types of orthodontic alloy wires (nickel–titanium (NiTi), coated NiTi, stainless steel (SS), Ni-free SS, and cobalt–chromium (CoCr) and titanium–molybdenum (TMA) were immersed into artificial saliva of pH 5.5 and 6.6. Release of metal ions was measured by inductively coupled plasma–mass spectrometry after 3, 7, 14 and 28 days. The data were analyzed using analysis of variance, and results with p < 0.05 were considered significant. NiTi released more Ti and Ni ions compared to the coated NiTi; SS released more iron, chromium, and nickel compared to the nickel-free SS. CoCr released cobalt in a high concentration and low amounts of chromium, nickel, and molybdenum compared to the molybdenum and titanium released by TMA. Release of metals from dental orthodontic alloys in vitro was overall lower at pH 6.6 and for the hypoallergenic equivalents when compared to standard dental alloys.Keywords
Funding Information
- University of Rijeka (uniri-iskusni-biomed-23-36, CroRIS ID 8071)
- Faculty of Dental Medicine, University of Rijeka (uniri-iskusni-biomed-23-36, CroRIS ID 8071)
This publication has 35 references indexed in Scilit:
- Nickel and chromium ion release from coated and uncoated orthodontic archwires under different pH levels and exposure timesJournal of Oral Biosciences, 2021
- Titanium exposure and human healthOral Science International, 2019
- The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwiresMaterials Science and Engineering: C, 2017
- Release of titanium ions from an implant surface and their effect on cytokine production related to alveolar bone resorptionToxicology, 2015
- The role of fluoride on the process of titanium corrosion in oral cavityBioMetals, 2012
- Corrosion of alloys used in dentistry: A reviewMaterials Science and Engineering: A, 2006
- The effect of surface treatment and clinical use on friction in NiTi orthodontic wiresDental Materials, 2005
- Nickel ion release from orthodontic NiTi wires under simulation of realistic in-situ conditionsJournal of Materials Science, 2005
- Biological interactions of dental cast alloys with oral tissuesDental Materials, 2002
- Dental Materials: Biocompatibility2002