An Improved IGBT Short-Circuit Protection Method With Self-Adaptive Blanking Circuit Based on V CE Measurement

Authors:

Abstract
IGBT short-circuit protection is the key factor to improve the reliability of the power electronics system. The conventional short-circuit protection method based on V CE measurement detects the collector-emitter voltage of an IGBT to determine whether the IGBT short-circuit fault occurs. The blanking circuit is needed in this kind of protection method to avoid the false triggering of the short-circuit protection during IGBT turn-on transient. However, this blanking circuit should be carefully designed for different types of IGBT modules. In order to make the IGBT short-circuit protection circuit suitable for the tolerance of IGBT modules, a self-adaptive blanking circuit combined with the aforementioned short-circuit protection method based on V CE measurement is proposed. The proposed method is achieved by feeding back the required minimum blanking time interval which is decided by comparing the desaturation reference voltage with the collector-emitter voltage. The short-circuit protection delay time for the conventional circuit and the proposed circuit are compared. Experimental results are included to prove the effectiveness of the proposed circuit.
Funding Information
  • National Natural Science Foundation of China (51477152)
  • National Natural Science Foundation of China (51337009)

This publication has 19 references indexed in Scilit: