A proposed alternative to phase-space recycling using the adaptive kernel density estimator method
Authors:
- William R. MartinWMWilliam R. Martin
- J. DuJDJ. Du
- A. F. BielajewABA. F. Bielajew
- Indrin J. ChettyICIndrin J. Chetty
- 31 January 2006
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 33 (2) , 553-560
Abstract
We have implemented a nonparametric density estimation technique, the adaptive kernel density estimator (AKDE), to generate additional phase space (PS) variables in the vicinity of simulated PS points in Monte Carlo linear accelerator simulation. The method involves the placement of kernels at simulated PS points that have a "window width" that depends on the density of simulated PS points. This method has been tested on known one-dimensional (I-D) and two-dimensional (2-D) probability density functions (PDFs) and has been used to sample (photons only) from PS files generated from accelerator simulations. The original simulated PS vector (x, y, u, v, E) was reduced to a rotationally invariant PS vector (r, theta, alpha, E) that takes advantage of the azimuthal symmetry (phi) above the collimating jaws. The new PS vector (r', theta', alpha', E) is sampled in the vicinity of the sampled PS vector (r, 0, a, E). The first step in assessing the accuracy of the method was a correlation analysis among the AKDE generated PS variables compared with correlations among the original PS variables. "In-air" particle fluence distributions between AKDE samples and the original PS distribution showed agreement within 2% (-8.8% to 6.8%) across the entire phase space plane. Central axis energy distributions and angular distributions agreed on average to within 1.5% (range=-1.5% to 6.6%) and 0.1% (range=0 to 3.0%), respectively. Dose profiles were calculated for field sizes 3 x 3 cm(2), 10 x 10 cm(2), and 30 x 30 cm(2) for AKDE and compared against calculations performed with PS recycling. AKDE calculated depth doses and profiles were within 2% and 2%/1 mm, respectively, of those computed using PS recycling. (c) 2006 American Association of Physicists in Medicine.Keywords
Funding Information
- National Institutes of Health (R01 CA106770, P01-CA59827)
This publication has 4 references indexed in Scilit:
- Photon beam relative dose validation of the DPM Monte Carlo code in lung‐equivalent mediaMedical Physics, 2003
- History by history statistical estimators in the BEAM code systemMedical Physics, 2002
- DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculationsPhysics in Medicine & Biology, 2000
- Density Estimation for Statistics and Data Analysis1986