Abstract
Current ultrasonic blood flow measurement systems estimate only that component of flow which is parallel to the incident ultrasound beam. This is done by relating the mean backscattered frequency shift to the axial velocity component through the classical Doppler equation. A number of ultrasonic techniques for estimating the two-dimensional (2D) blood velocity vector have been published, both Doppler and non-Doppler. Several three-dimensional (3D) blood velocity vector techniques have also been proposed, all of which require a multiplicity of transducers or lines of sight. Here a technique is described for estimating the total velocity vector, using only two transducers. This is achieved by measuring not only the frequency shifts but also the bandwidths of the backscattered spectra, making use of the fact that the bandwidth of a Doppler spectrum has been shown to be proportional to the velocity component normal to the sound beam. Partial experimental verification of the proposed vector flow estimation scheme is demonstrated by using a constant velocity thread phantom.<>Keywords
This publication has 16 references indexed in Scilit:
- On the spectral properties of Doppler thread phantomsUltrasound in Medicine & Biology, 1994
- Comparison of conventional and transverse Doppler sonogramsJournal of Ultrasound in Medicine, 1993
- Transverse doppler spectral analysis for a correct interpretation of flow sonogramsUltrasound in Medicine & Biology, 1993
- A novel method for angle independent ultrasonic imaging of blood flow and tissue motionIEEE Transactions on Biomedical Engineering, 1991
- A triangulation method for the quantitative measurement of arterial blood velocity magnitude and direction in humansUltrasound in Medicine & Biology, 1990
- Restoration of the velocity field of the heart from two-dimensional echocardiogramsIEEE Transactions on Medical Imaging, 1989
- Clinical evaluation of a new anti-aliasing technique for ultrasound pulsed Doppler analysisUltrasound in Medicine & Biology, 1989
- Angle independent ultrasonic blood flow detection by frame-to-frame correlation of B-mode imagesUltrasonics, 1988
- Theory of ultrasound Doppler-spectra velocimetry for arbitrary beam and flow configurationsIEEE Transactions on Biomedical Engineering, 1988
- Ultrasound Doppler Probing of Flows Transverse with Respect to Beam AxisIEEE Transactions on Biomedical Engineering, 1987