Dispersive liquid–liquid microextraction as an effective preanalytical step for the determination of estradiol in human urine
- 11 May 2017
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 40 (12) , 2620-2628
Abstract
In this work, a fast and effective dispersive liquid–liquid microextraction was developed for the isolation and preconcentration of free 17 β‐estradiol, the main human estrogen, from real human urine samples. To optimize the extraction technique, few important parameters such as type and volume of extraction and dispersive solvents, centrifugation conditions, effect of salt addition, and extraction time were studied. Optimal conditions were obtained when injecting 600 μL mixture of tetrachloromethane as extraction solvent and ethanol as dispersive solvent (1:5, v/v) into 2 mL of urine containing 8% NaCl and following centrifugation at 10 000 rpm, thus reaching enrichment factor 28 and extraction recovery 98% for estradiol. Procedure was evaluated by means of high‐performance liquid chromatography with UV detection (λ = 280 nm) using a C‐18 column and methanol/water (60:40, v/v) as the mobile phase. The method was linear within the concentration range 1.0–250.0 mg/L (r = 0.9997) and provided a limit of detection of 0.25 mg/L. The proposed method was applied to the determination of free estradiol in real human pregnancy urine.Keywords
Funding Information
- scientific grant agency of the ministry of education of the Slovak republic and of Slovak academy of sciences
This publication has 57 references indexed in Scilit:
- Urinary Estrogens and Estrogen Metabolites and Subsequent Risk of Breast Cancer among Premenopausal WomenCancer Research, 2012
- Tissue-Specific Effects of Loss of Estrogen during Menopause and AgingFrontiers in Endocrinology, 2012
- Determination of steroid hormones in biological and environmental samples using green microextraction techniques: An overviewAnalytica Chimica Acta, 2011
- Dispersive liquid-liquid microextractionTrAC Trends in Analytical Chemistry, 2011
- Microwave‐accelerated derivatization prior to GC‐MS determination of sex hormonesJournal of Separation Science, 2011
- Determination of the steroid hormone levels in water samples by dispersive liquid–liquid microextraction with solidification of a floating organic drop followed by high-performance liquid chromatographyAnalytica Chimica Acta, 2010
- Determination of Estrone and 17β-Estradiol in Water Samples Using Dispersive Liquid–Liquid Microextraction Followed by LCChromatographia, 2009
- Analysis for estrogens as environmental pollutants – A reviewJournal of Separation Science, 2009
- Novel analytical methods for the determination of steroid hormones in edible matricesAnalytica Chimica Acta, 2008
- Validation of a quantitative assay using GC/MS for trace determination of free and conjugated estrogens in environmental water samplesJournal of Separation Science, 2003