Fetal Ventricular Mass Determination on Three-Dimensional Echocardiography
Authors:
- 31 August 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 110 (9) , 1054-1060
Abstract
Background— Estimation of ventricular volume and mass is important for baseline and serial evaluation of fetuses with normal or abnormal hearts. Direct measurement of chamber wall volumes and mass can be made without geometric assumptions by 3D fetal echocardiography. Our goals were to determine the feasibility of using fast nongated 3D echocardiography for fetal volumetric and mass assessments, to validate the accuracy of the ultrasound system and the measurement technique, and if satisfactory, to develop normal values for fetal ventricular mass during the second and third trimesters. Methods and Results— This was a prospective outpatient study of 90 consecutive normal pregnancies during routine obstetric services at Oregon Health & Science University (Portland). Optimized 3D volumes of the fetal thorax and cardiac chambers were rapidly acquired and later analyzed for right and left ventricular mass by radial summation technique from manual epicardial and endocardial traces. Experiments to validate the ultrasound system and measurement technique were performed with modified small balloon models and in vivo and ex vivo small animal experiments. Our study established the feasibility of fetal ventricular mass measurements with 3D ultrasound technology and developed normal values for right and left ventricular mass from 15 weeks’ gestation to term. Conclusions— Nongated fast 3D fetal echocardiography is an acceptable modality for determination of cardiac chamber wall volume and mass with good accuracy and acceptable interobserver variability. The method should be especially valuable as an objective serial measurement in clinical fetal studies with structurally or functionally abnormal hearts.Keywords
This publication has 32 references indexed in Scilit:
- Left Ventricular MassHypertension, 2002
- Sources and impact of artifacts on clinical three‐dimensional ultrasound imagingUltrasound in Obstetrics & Gynecology, 2000
- Biometry of the Fetal Heart between 10 and 17 Weeks of GestationFetal Diagnosis and Therapy, 2000
- Fetal lung volumetry by three‐dimensional ultrasoundUltrasound in Obstetrics & Gynecology, 1998
- Quantitative three dimensional echocardiography in patients with pulmonary hypertension and compressed left ventricles: comparison with cross sectional echocardiography and magnetic resonance imaging.Heart, 1996
- Determination ef ventricular volumes in human fetal hearts by two-dimensional echocardiographyThe American Journal of Cardiology, 1995
- Echocardiographic evaluation of dilated cardiomyopathy in the human fetusThe American Journal of Cardiology, 1989
- Congenital heart disease in a cohort of 19,502 births with long-term follow-upThe American Journal of Cardiology, 1978
- Echocardiographic determination of left ventricular mass in man. Anatomic validation of the method.Circulation, 1977
- Congenital Heart Disease in 56,109 Births Incidence and Natural HistoryCirculation, 1971