Abstract
The damper (or amortisseur) winding of synchronous motors (SM) is a critical component required for starting the motor. Several cases of forced outage of industrial processes due to starting failure of salient pole SMs caused by damper bar failure have recently been reported. Detection of broken damper bars is difficult since they are active only during rotor acceleration, and off-line visual inspection is the only means of testing available in the field. It was recently shown that broken damper bars can be detected from the airgap flux, but this requires installation of airgap flux sensors inside the motor. In this paper, a method based on analysis of the stator starting current is proposed for detecting broken damper bars. In addition, an electrical detection method based on signal injection from the motor terminals is proposed. The new methods have been devised to provide remote testing from the motor control center without motor disassembly required in existing tests. Finite element (FE) analysis and experimental testing performed on 1 MW and 30 kW salient pole SMs with emulated broken damper bars show that the proposed methods can provide sensitive and reliable detection of damper bar failures.
Funding Information
  • National Research Foundation of Korea
  • Korea government (NRF-2019R1A2C1084104)

This publication has 19 references indexed in Scilit: