High-Temperature Potentiometry: Modulated Response of Ion-Selective Electrodes During Heat Pulses
Authors:
- Chongdee ThammakhetCTChongdee Thammakhet
- Michal GalikMGMichal Galik
- Percy Calvo-MarzalPCPercy Calvo-Marzal
- Jie WuJWJie Wu
- Eric BakkerEBEric Bakker
- Gerd-Uwe FlechsigGFGerd-Uwe Flechsig
- Joseph WangJoseph Wang
- 20 November 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (24) , 10290-10294
Abstract
The concept of locally heated polymeric membrane potentiometric sensors is introduced here for the first time. This is accomplished in an all solid state sensor configuration, utilizing poly(3-octylthiophene) as the intermediate layer between the ion-selective membrane and underlying substrate that integrates the heating circuitry. Temperature pulse potentiometry (TPP) gives convenient peak-shaped analytical signals and affords an additional dimension with these sensors. Numerous advances are envisioned that will benefit the field. The heating step is shown to give an increase in the slope of the copper-selective electrode from 31 to 43 mV per 10-fold activity change, with a reproducibility of the heated potential pulses of 1% at 10 μM copper levels and a potential drift of 0.2 mV/h. Importantly, the magnitude of the potential pulse upon heating the electrode changes as a function of the copper activity, suggesting an attractive way for differential measurement of these devices. The heat pulse is also shown to decrease the detection limit by half an order of magnitude.Keywords
This publication has 24 references indexed in Scilit:
- Electrochemical product detection of an asymmetric convective polymerase chain reactionBiosensors and Bioelectronics, 2009
- Thin layer electrochemical extraction of non-redoxactive cations with an anion-exchanging conducting polymer overlaid with a selective membraneChemical Communications, 2009
- Elimination of Undesirable Water Layers in Solid-Contact Polymeric Ion-Selective ElectrodesAnalytical Chemistry, 2008
- Aptamer-Based Potentiometric Measurements of Proteins Using Ion-Selective MicroelectrodesAnalytical Chemistry, 2008
- DNA Hybridization Detection at Heated ElectrodesLangmuir, 2005
- A novel polymeric membrane electrode for the potentiometric analysis of Cu2+ in drinking waterAnalytica Chimica Acta, 2005
- Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar rangeAnalytica Chimica Acta, 2004
- Hot-wire stripping potentiometric measurements of trace mercuryAnalytica Chimica Acta, 1999
- Determination of Unbiased Selectivity Coefficients of Neutral Carrier-Based Cation-Selective ElectrodesAnalytical Chemistry, 1997
- Hot-wire electrodes: voltammetry above the boiling pointThe Analyst, 1996