Bearing-Foreign Material Deposition on Retrieved Co-Cr Femoral Heads: Composition and Morphology
Open Access
- 5 July 2015
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-9
Abstract
Bearing-foreign material deposition onto a femoral head can occur from contact with an acetabular shell due to dislocation, reduction, or subluxation. The purpose of this study was to comprehensively characterize deposit regions on retrieved cobalt-chrome femoral heads from metal-on-polyethylene total hip arthroplasties that had experienced such adverse events. The morphology, topography, and composition of deposition regions were characterized using macrophotography, optical profilometry, scanning electron microscopy, energy dispersive spectroscopy, and X-ray photoelectron spectroscopy. The deposit areas were relatively large, they were much rougher than the surrounding undamaged clean areas, and they displayed several distinct morphologies. Titanium alloy elements were the predominant constituents. Calcium and phosphorous were also detected within the deposit areas, in a composition that could nucleate abrasive hydroxyapatite. In addition, tungsten-rich particles, likely present as tungsten carbide, were observed on top of the titanium deposits. The increased roughness associated with these deposition features would be expected to accelerate damage and wear of the opposing liner and hence accelerate the development of osteolysis.Keywords
Funding Information
- National Institutes of Health (AR057780)
This publication has 28 references indexed in Scilit:
- Encoding Scratch and Scrape Features for Wear Modeling of Total Joint ReplacementsComputational and Mathematical Methods in Medicine, 2013
- Unique Roles of Acidic Amino Acids in Phase Transformation of Calcium PhosphatesThe Journal of Physical Chemistry B, 2010
- Surface Roughness of CoCr and ZrO2 Femoral Heads with Metal Transfer: A Retrieval and Wear Simulator StudyInternational Journal of Biomaterials, 2009
- In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high‐resolution TEM and XPS analysesJournal of Biomedical Materials Research Part A, 2008
- Transfer of metallic debris from the metal surface of an acetabular cup to artificial femoral heads by scraping: Comparison between alumina and cobalt–chrome headsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Damage of Oxinium Femoral Heads Subsequent to Hip Arthroplasty DislocationThe Journal of Arthroplasty, 2007
- Three-dimensional laser micrometry characterization of surface wear in total hip arthroplastyJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Arthroplasty Options for the Young PatientClinical Orthopaedics and Related Research, 2005
- Quantitative evaluation of the prosthetic head damage induced by microscopic third‐body particles in total hip replacementJournal of Biomedical Materials Research, 2001
- In Vivo Wear of 3 Types of Metal on Metal Hip Prostheses During 2 Decades of UseClinical Orthopaedics and Related Research, 1996