Frequency Subsampling of Ultrasound Nondestructive Measurements: Acquisition, Reconstruction, and Performance
- 31 May 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (10) , 3174-3191
Abstract
In ultrasound nondestructive testing (NDT), a widespread approach is to take synthetic aperture measurements from the surface of a specimen to detect and locate defects within it. Based on these measurements, imaging is usually performed using the synthetic aperture focusing technique (SAFT). However, SAFT is suboptimal in terms of resolution and requires oversampling in the time domain to obtain a fine grid for the delay-and-sum (DAS). On the other hand, parametric reconstruction algorithms give better resolution, but their usage for imaging becomes computationally expensive due to the size of the parameter space and a large amount of measurement data in realistic 3-D scenarios when using oversampling. In the literature, the remedies to this are twofold. First, the amount of measurement data can be reduced using state-of-the-art sub-Nyquist sampling approaches to measure Fourier coefficients instead of time-domain samples. Second, parametric reconstruction algorithms mostly rely on matrix–vector operations that can be implemented efficiently by exploiting the underlying structure of the model. In this article, we propose and compare different strategies to choose the Fourier coefficients to be measured. Their asymptotic performance is compared by numerically evaluating the Cramér–Rao bound (CRB) for the localizability of the defect coordinates. These subsampling strategies are then combined with an $\ell _{{1}}$ -minimization scheme to compute 3-D reconstructions from the low-rate measurements. Compared to conventional DAS, this allows us to formulate a fully physically motivated forward model matrix. To enable this, the projection operations of the forward model matrix are implemented matrix-free by exploiting the underlying two-level Toeplitz structure. Finally, we show that high-resolution reconstructions from as low as a single Fourier coefficient per A-scan are possible based on simulated data and measurements from a steel specimen.Keywords
All Related Versions
Funding Information
- Fraunhofer Internal Programs (Attract 025-601128)
- Deutsche Forschungsgemeinschaft (DFG) through the project “HoPa-Dyn” (TH 494/30-1)
- Carl-Zeiss-Stiftung through the project “PRIME.”
- DFG through the project “CoSMaDU” (GA 2062/5-1)
This publication has 45 references indexed in Scilit:
- Correlation-based imaging technique using ultrasonic transmit–receive array for Non-Destructive EvaluationUltrasonics, 2012
- Synthetic Aperture Focusing and Time-of-Flight Diffraction Ultrasonic Imaging—Past and PresentJournal of Nondestructive Evaluation, 2012
- Sparsity driven ultrasound imagingThe Journal of the Acoustical Society of America, 2012
- Compressed sensing with coherent and redundant dictionariesApplied and Computational Harmonic Analysis, 2011
- New and Improved Johnson–Lindenstrauss Embeddings via the Restricted Isometry PropertySIAM Journal on Mathematical Analysis, 2011
- A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse ProblemsSIAM Journal on Imaging Sciences, 2009
- Built-in Sensor Network for Structural Health Monitoring of Composite StructureJournal of Intelligent Material Systems and Structures, 2007
- Post-processing of the full matrix of ultrasonic transmit–receive array data for non-destructive evaluationNDT & E International, 2005
- Deflation Techniques for an Implicitly Restarted Arnoldi IterationSIAM Journal on Matrix Analysis and Applications, 1996