Use of Rotating Cylinder Electrodes to Simulate Turbulent Flow Conditions in Corroding Systems
Authors:
- R.A. HolserRHR.A. Holser
- 1 September 1990
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 46 (9) , 764-769
Abstract
Rotating electrodes are used to model flow conditions in electrochemical systems where mass transfer affects the reaction rate. Mass transfer correlations are used to relate the model system to the prototype system through equivalence of the limiting current densities. This approach is used to apply laboratory polarization data obtained with rotating cylinder electrodes to corroding systems in turbulent flow conditions. Results of this technique are described for cathodic protection design in marine environments.Keywords
This publication has 12 references indexed in Scilit:
- Rotating Cylinder Electrode — Geometry Relationships for Prediction of Velocity-Sensitive CorrosionCorrosion, 1988
- Rotating Cylinder Electrode for Velocity Sensitivity TestingCorrosion, 1984
- The rotating cylinder electrode: a review of developmentJournal of Applied Electrochemistry, 1983
- The Solubility of Oxygen in Brines from 0 to 300 °CIndustrial & Engineering Chemistry Process Design and Development, 1980
- The rotating cylinder electrodeJournal of Applied Electrochemistry, 1974
- Diffusivity of oxygen in electrolyte solutionsJournal of Chemical & Engineering Data, 1972
- Mass Transfer to a Rough Rotating CylinderJournal of the Electrochemical Society, 1971
- Dissolution of Metals in Aqueous Acid SolutionsJournal of the Electrochemical Society, 1958
- Ionic Mass Transfer and Concentration Polarization at Rotating ElectrodesJournal of the Electrochemical Society, 1954