On the Maximum Bandwidth Attainable by Power Factor Correctors With a Standard Compensator
- 1 July 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 46 (4) , 1485-1497
Abstract
When a power factor corrector (PFC) is designed with a relatively fast output-voltage feedback loop, the static and dynamic behaviors of the power stage are different from those obtained with a slow output-voltage feedback loop. This is because of the influence of the voltage ripple that is present on the control signal. This voltage ripple generates a “parasitic” feedback loop, which is different from the “desired” one (the dc output-voltage feedback loop). The effect of this “parasitic” feedback loop can be integrated into the power stage model in such a way that a new model for the power stage is obtained. Assuming this model, the only feedback loop is the one corresponding to the dc output voltage, i.e., the “desired” output-voltage feedback loop. The design of this feedback loop determines the final dynamic behavior of the PFC, which can be optimized to achieve the maximum bandwidth compatible with compliance with existing regulations regarding the injection of line harmonics and PFC stability. The main objective of this paper is, thus, to determine the maximum crossover angular frequency ω0 compatible with a desired value of the phase margin φm and that complies with EN 61000-3-2 regulations in all possible classes of equipment (A, B, C, and D) when a standard compensator (a PI with one additional pole) is used. The results obtained show that the maximum bandwidth attainable by a PFC strongly depends on its class. This maximum bandwidth depends on the power processed by the converter in the case of equipment classified as Class A or Class B. However, the maximum bandwidth attainable for equipment belonging to Class C or to Class D does not depend on the power processed and is always higher in the case of Class D than in that of Class C.Keywords
This publication has 20 references indexed in Scilit:
- A Simple Method to Improve the Dynamic Response of Single-Phase PWM RectifiersIEEE Transactions on Industrial Electronics, 2008
- A Unity Power Factor Correction Preregulator With Fast Dynamic Response Based on a Low-Cost MicrocontrollerIEEE Transactions on Power Electronics, 2008
- Dynamic Limits of a Power-Factor PreregulatorIEEE Transactions on Industrial Electronics, 2005
- Off-line flyback converter with input harmonic current correction2002
- Single-stage, single-switch, isolated power supply technique with input-current shaping and fast output-voltage regulation for universal input-voltage-range applications2002
- A topology survey of single-stage power factor corrector with a boost type input-current-shaperIEEE Transactions on Power Electronics, 2001
- Improved active input current shapers for converters with symmetrically driven transformerIEEE Transactions on Industry Applications, 2001
- Input current shaper based on the series connection of a voltage source and a loss-free resistorIEEE Transactions on Industry Applications, 2001
- Design optimization of single-stage single-switch input-current shapersIEEE Transactions on Power Electronics, 2000
- Analysis and design of a single stage power factor corrected full-bridge converter1999