Electric Field Probe Used for Gradient Coil-Induced Field Measurements During Medical Device Testing: Design, Calibration, and Validation
- 9 January 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 68 (5) , 4029-4037
Abstract
In this work an ultra-low frequency electric field probe capable of measuring time varying gradient coil induced electric fields in a tissue mimicking material was constructed, calibrated and validated. This probe consisted of a 2 cm short dipole antenna followed by an instrumentation. The designed amplifier had a gain of 100 and a cut-off frequency of 31 kHz. The probe was fabricated on a 4-layer printed circuit board (PCB), FR4 of thickness 1.57 mm and a copper thickness of 35 μm. A waterproofed 3D probe holder was used to cover the electronics and expose the dipole tip to the saline solution. To calibrate this probe in a known environment a parallel-plate conductor was used. The calibrated probe was validated by measuring the electric field in a saline filled cylindrical phantom placed within a cylindrically symmetric test coil. In order to do the validation, simulations were performed using an in-house tool developed in MATLAB and a validated tool in Sim4Life.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- Ontario Research Fund
- CMC Microsystems
This publication has 12 references indexed in Scilit:
- Magnetic field probes for time‐domain monitoring of RF exposure within tissue‐mimicking materials for MRI‐compatible medical device testingElectronics Letters, 2018
- Reliable RF B/E-Field Probes for Time-Domain Monitoring of EM Exposure During Medical Device TestingIEEE Transactions on Antennas and Propagation, 2017
- Time-domain monitoring of EM exposure during medical device testing2017
- Electric field probe using a differential amplifier circuit with high input impedance2015
- Compensation of electric cross-field response in shielded loop probeElectronics Letters, 2011
- In-vitro mapping of E-fields induced near pacemaker leads by simulated MR gradient fieldsBioMedical Engineering OnLine, 2009
- Measurement of electric fields due to time-varying magnetic field gradients using dipole probesPhysics in Medicine & Biology, 2007
- Can patients with implantable pacemakers safely undergo magnetic resonance imaging?**Editorials published in the Journal of the American College of Cardiologyreflect the views of the authors and do not necessarily represent the views of JACCor the American College of Cardiology.JACC, 2004
- RF safety of wires in interventional MRI: Using a safety indexMagnetic Resonance in Medicine, 2001
- Standard probes for electromagnetic field measurementsIEEE Transactions on Antennas and Propagation, 1993