Investigating confounding factors in shear wave speed measurements of fibrotic liver tissues: a computer simulation study
Open Access
- 3 March 2026
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (2) , 1-11
Abstract
Screening patients with liver fibrosis and identifying those at risk of developing advanced liver fibrosis is of clinical interest. Shear wave elastography (SWE), a promising non-invasive screening tool used to distinguish healthy tissue from diseased tissue, measures tissue shear wave speed (SWS) to describe tissue stiffness and identify liver fibrosis. However, considerable variations in the reported results have been found. We propose that the heterogeneity of the liver tissue background, such as the presence of fatty liver tissue and the preferred local orientation of the scarred fibrotic liver tissues embedded into the liver parenchyma, may contribute to the uncertainty in SWE measurements. Therefore, this study aims to systematically investigate four cofounding factors, the size, volume fraction, and orientation of the fibrotic inclusions, as well as the fatty background, using computer simulations, to describe the multifaceted impact on SWS variability (i.e., SWS standard deviation). The simulations implemented in this preliminary study demonstrated that both fibrosis and fatty background impact the SWS STD and that the SWS STD distributions do not follow a Gaussian distribution. While the SWS STD increased with fibrosis size and volume fraction, the SWS STD decreased as the fatty background increased. The shape of the distribution did not follow a consistent trend across fibrosis inclusion levels, fibrosis sizes, fibrosis orientations, and percent fatty background for either the Mean SWS or the SWS STD. The current study provided evidence that the current clinical guidelines, regarding cut-off values for the different METAVIR Fibrosis stages, overestimate the fibrosis levels in the presence of steatosis.Keywords
This publication has 50 references indexed in Scilit:
- Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: A pilot studyHepatology, 2012
- Liver Stiffness Measurements in Patients with Different Stages of Nonalcoholic Fatty Liver Disease: Diagnostic Performance and Clinicopathological CorrelationDigestive Diseases and Sciences, 2012
- Reliability of transient elastography for the detection of fibrosis in Non-Alcoholic Fatty Liver Disease and chronic viral hepatitisJournal of Hepatology, 2011
- Diagnosis of Fibrosis and Cirrhosis Using Liver Stiffness Measurement in Nonalcoholic Fatty Liver DiseaseHepatology, 2010
- k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fieldsJournal of Biomedical Optics, 2010
- Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 ExaminationsHepatology, 2009
- Quantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation ForceUltrasound in Medicine & Biology, 2008
- Acute viral hepatitis increases liver stiffness values measured by transient elastographyHepatology, 2008
- Transient elastography in patients with non-alcoholic fatty liver disease (NAFLD)Gut, 2007
- Sampling Variability of Liver Biopsy in Nonalcoholic Fatty Liver DiseaseGastroenterology, 2005