Clinical outcomes and costs of reusable and single-use flexible ureterorenoscopes: a prospective cohort study
Authors:
- 22 January 2018
- journal article
- research article
- Published by Springer Nature in Urolithiasis
- Vol. 46 (6) , 587-593
Abstract
The purpose of this study is to analyze clinical outcomes and costs of single-use flexible ureterorenoscopes in comparison with reusable flexible ureterorenoscopes in a tertiary referral center. Prospectively, 68 flexible ureterorenoscopies utilizing reusable (Flex-X2S, Flex-XC, Karl Storz) and 68 applying single-use flexible ureterorenoscopes (LithoVue, Boston Scientific) were collected. Clinical outcome parameters such as overall success rate, complication rates according to Clavien–Dindo, operation time and radiation exposure time were measured. Cost analysis was based on purchase costs and recurrent costs for repair and reprocessing divided by number of procedures. In each group 68 procedures were available for evaluation. In 91% of reusable and 88% of single-use ureterorenoscopies stone disease was treated with a mean stone burden of 101 ± 226 and 90 ± 244 mm2 and lower pole involvement in 47 and 41%, respectively (p > 0.05). Comparing clinical outcomes of reusable vs. single-use instruments revealed no significant difference for overall success rates (81 vs. 87%), stone-free rates (82 vs. 85%), operation time (76.2 ± 46.8 vs. 76.8 ± 40.2 min), radiation exposure time (3.83 ± 3.15 vs. 3.93 ± 4.43 min) and complication rates (7 vs. 17%) (p > 0.05). A wide range of repair and purchase costs resulted in total to $1212–$1743 per procedure for reusable ureterorenoscopy whereas price of single-use ureterorenoscopy was $1300–$3180 per procedure. The current work provided evidence for equal clinical effectiveness of reusable and single-use flexible ureterorenoscopes. Partially overlapping ranges of costs for single-use and reusable scopes stress the importance to precisely know the expenses and caseload when negotiating purchase prices, repair prices and warranty conditions.Keywords
This publication has 28 references indexed in Scilit:
- Outcomes of Flexible Ureterorenoscopy and Laser Fragmentation for Renal Stones: Comparison Between Digital and Conventional UreteroscopeUrology, 2013
- Decreasing the Cost of Flexible Ureterorenoscopic ProceduresUrology, 2011
- Is There a Difference in Outcomes Between Digital and Fiberoptic Flexible Ureterorenoscopy Procedures?Journal of Endourology, 2010
- Durability of the Next-generation Flexible Fiberoptic Ureteroscopes: A Randomized Prospective Multi-institutional Clinical TrialUrology, 2010
- Ureteroscope Cleaning and Sterilization by the Urology Operating Room Team: The Effect on Repair CostsJournal of Endourology, 2009
- Frequency of Ureteroscope Damage Seen at a Tertiary Care CenterJournal of Urology, 2006
- Durability of Flexible Ureteroscopes: A Randomized, Prospective StudyJournal of Urology, 2006
- Performance and Durability of Leading Flexible UreteroscopesJournal of Endourology, 2004
- Classification of Surgical ComplicationsAnnals of Surgery, 2004
- Cost analysis of flexible ureterorenoscopyBJU International, 2004